Maintenance
49
up the rebuild operation should start and be indicated in the status
line. The system can be used immediately, but if possible allow the
RAID to finish rebuilding before putting the system back in service. If
the Recording process starts automatically, simply click the Stop button
in the GUI.
A hard disk array ideally should be repaired using the same drive model
and capacity as other drives in the array. Because specific drive
models become unavailable as time goes on, 360 Systems recommends that
maintenance spares be purchased at the same time as the server. It is
possible to use a larger drive than the original; in this case the drive
will be partitioned to match the size of the original.
When ordering spare drives, note carefully which model TSS-2470 Time
Delay you have as the drives may vary depending on the model.
The server hard disk drives have been factory tested and configured in
a RAID 5 array. Each drive is numbered (0-3) and must be attached to
the correctly numbered data cable. Drive bays are also numbered.
Please read
Removing the Front Panel
on page 45 for instructions on
accessing the hard drive bays.