Maintenance
49
Rebuilding the RAID Array
Figure 7: Selecting a Drive to Use in Rebuilding the Array
•
Take the Time Delay offline and stop the delay process.
•
Select
Rebuild Unit
. The REBUILD SCREEN above will appear.
•
Select the available drive by clicking the check box.
•
Press
OK
. The RAID array will begin rebuilding with the new drive.
•
When complete, OK will be shown in the status for all ports on the MAINTENANCE menu.
Replacing Hard Drives
The server hard disk drives have been factory tested and configured in a RAID 5 array. Each drive
is numbered (0-3) and must be attached to the correctly numbered data cable. Drive bays are also
numbered.
Please read
Removing the Front Panel
on page 38 for instructions on accessing the hard drive bays.
Detailed information about how to replace hard drives is on page 51.