39 / 51
www.selea.com
Integrated I/O
It can be used to configure the behaviour of the two digital
inputs of
iZero
, meaning which electric variation must be
detected to generate a reason for an event. It is possible
to decide if the event must start on completion of the
variation (level) or while the variation is being performed
(front). To make things easier,
iZero
shows a drawing that
indicates with a red dash which electric phenomenon will
be the triggering event. Also in this screen, and solely to
make things easier, we have included the behaviour that
the digital output will need to maintain when used as
response action to an “event”.
Software button
It creates a
“button”
in the
home-page
of
iZero
,
which when pressed generates an
“event”
(to
which it will be possible to associate one or more
actions, such as the manual opening of the bar).
A name may be assigned to the button in the field
below.