Installation manual 2N® IP Force
64
/
118
•
1.
2.
3.
a.
b.
c.
4.
5.
6.
7.
a.
b.
c.
8.
9.
Tamper switch: 24 V / 50 mA AC/DC
Module mounting:
Switch off the intercom.
Remove the front panel from the intercom.
According to your model
If you are mounting the switch into a two-nameplate model, demount the button PCB (1) and remove
the right-hand bottom spacer (there are four PCB fitting spacers altogether).
If you are mounting the switch into a keypad model, take the keypad out of the holder. Demount the
right-hand keypad holder – beam with a pin (8) – remembering its position. Demount the right-hand
bottom spacer. Do not disconnect the keypad cable!
If you are mounting the switch into a model other than the two ones mentioned in items 3a and 3b
above, remove the right-hand bottom screw from the main board.
Now screw the enclosed 12 mm spacer (5) into the vacated main board slot.
Mount the enclosed plastic support (6) onto the switch board bottom side.
Put the switch board (4) in the main board connector making sure that the screw hole is directly above the
spacer.
According to your model
If you are mounting the switch into a two-nameplate model, fit the switch board with the enclosed
10.5 mm spacer (3) and reinstall the button PCB (1).
If you are mounting the switch into a keypad model, reinstall the beam (8) of the keypad holder (the
slot is on top). Insert the enclosed 4.5 mm washer (9) between the beam and the switch board, fitting
the assembly with the 15 mm screw enclosed (7).
If you are mounting the switch into a model other than the two ones mentioned in items 7a and 7b, fit
the switch board with the original 6 mm screw (2).
If you want to use the tamper switch, insert the tamper board (9) in the connector located in the right-hand
bottom part of the switch board (4). As the tamper switch shares the relay output (NO and NC) terminals, you
cannot use the RELAY2 output with the tamper switch together.
Place front panel back and tighten all four screws.
Summary of Contents for IP Force 9151101CHKW
Page 1: ...Installation manual 2N IP Force v 2 18 www 2n com ...
Page 49: ...Installation manual 2N IP Force 49 118 2N IP Force Connectors PCB Version 555v3 ...
Page 50: ...Installation manual 2N IP Force 50 118 2N IP Force Connectors PCB Version 555v4 ...
Page 65: ...Installation manual 2N IP Force 65 118 ...
Page 66: ...Installation manual 2N IP Force 66 118 ...
Page 70: ...Mounting guide ...
Page 72: ...Installation manual 2N IP Force 72 118 ...
Page 73: ...Module setting ...
Page 78: ...Installation manual 2N IP Force 78 118 ...
Page 79: ...Installation manual 2N IP Force 79 118 ...
Page 80: ...Module setting ...
Page 83: ...Active output ...
Page 85: ...Installation manual 2N IP Force 85 118 ...
Page 86: ...Installation manual 2N IP Force 86 118 ...
Page 87: ...Module setting ...
Page 89: ...Security Relay ...
Page 94: ...Installation manual 2N IP Force 94 118 Connection ...
Page 98: ...Installation manual 2N IP Force 98 118 ...