68
2N TELEKOMUNIKACE a.s., www.2n.cz
Parameter
Value
Conditions
Minimum required off-hook line current
15 mA
Off-hook
Minimum required on-hook line voltage
20 V
Hang-up
DC voltage drop (off-hook)
< 8 V < 16 V
I = 25 mA
I = 50 mA
Lead current while hang-up
< 25 μA
U = 60 V
Off-hook AC impedance
220 Ω + 820 Ω 115 nF
parallel
20 to 60
mA
Return loss
> 10 dB
20 to 60
mA
Bandwidth
300 to 3500 Hz
20 to 60
mA
Ringing impedance
> 2 kΩC = 1 μF
25 to 50 Hz
Ringing detector sensitivity
10 to 20 V
25 to 50 Hz
Time of response to ringing
Variable
Pulse dialling
40/60 ms
20 to 60
mA
DTMF level
−6 and 8 dB ±2 dB
−
20 to 60
mA
DTMF detector sensitivity
Min. 40 dB
−
20 to 60
mA
Dial tone detector sensitivity
Min. 40 dB
−
350 to 500
Hz
Busy tone detection speed
Variable
350 to 500
Hz
Continuous tone detection speed
Variable
350 to 500
Hz
Ringing tone detection speed
Variable
350 to 500
Hz
Overvoltage protection – common mode
1000 V
8/20 μs
Overvoltage protection – between A, B
conductors
1000 V
8/20 μs
Other Parameters
Switch – max. voltage
: 48 V AC, DC
Switch – min. voltage
: 9 V AC, DC
Switch – max. current
: 2 A AC, DC
Backlight – rated voltage
: 12 V
Backlight – max. voltage
: 14 V
Backlight – current consumption
: Up to 1 A
Working temperature
: −20 °C to +60 °C
Coverage
: IP 53
Dimensions (1 module)
: (210 × 100 × 29) mm
Weight
: up to 500g
Summary of Contents for Helios Vario
Page 1: ...www 2n cz Version 2N Helios Vario Door Access Intercom Installation Manual 1 1...
Page 7: ...7 2N TELEKOMUNIKACE a s www 2n cz...
Page 33: ...33 2N TELEKOMUNIKACE a s www 2n cz...
Page 37: ...37 2N TELEKOMUNIKACE a s www 2n cz...
Page 43: ...43 2N TELEKOMUNIKACE a s www 2n cz...
Page 58: ...58 2N TELEKOMUNIKACE a s www 2n cz pressing but not vice versa...
Page 65: ...65 2N TELEKOMUNIKACE a s www 2n cz 3 6 Downloads Templates Nametags...