![2N Helios Vario Installation Manual Download Page 27](http://html1.mh-extra.com/html/2n/helios-vario/helios-vario_installation-manual_3166792027.webp)
27
2N TELEKOMUNIKACE a.s., www.2n.cz
Grounding Terminal Connection – Mandatory
Any person that gets in contact with
may carry an electrostatic charge of
2N Helios
®
several thousands of Volts. Drawing one's finger near to the
metal panel
2N Helios
®
may result in spark discharge. The purpose of the grounding terminal is to protect the
product against this discharge. The terminal carries the charge from the panel to the
ground directly, not through the
circuits.
2N Helios
®
Where no grounding cable is available, it is possible to connect the grounding terminal
with any of the telephone line terminals*). In some telephone systems one line
terminal is directly connected with the ground, the others carry current to the ground
through overvoltage protection.
Separate Backlight and Electric Lock Supply
Separate power supplies are necessary where the lock requires voltage higher than 12
V. In this case, an additional power supply (12 V) must be used to illuminate the
button backlight – see the figure below. Other reasons for such connection are the
effort to minimise consumption from the back-up supply (which supplies the lock, not
the backlight), or just that two weaker power supplies are available
Note
This connection eliminates direct connection of the line conductor onto the
panel because there is a protective element between the panel and the
grounding terminal.
Summary of Contents for Helios Vario
Page 1: ...www 2n cz Version 2N Helios Vario Door Access Intercom Installation Manual 1 1...
Page 7: ...7 2N TELEKOMUNIKACE a s www 2n cz...
Page 33: ...33 2N TELEKOMUNIKACE a s www 2n cz...
Page 37: ...37 2N TELEKOMUNIKACE a s www 2n cz...
Page 43: ...43 2N TELEKOMUNIKACE a s www 2n cz...
Page 58: ...58 2N TELEKOMUNIKACE a s www 2n cz pressing but not vice versa...
Page 65: ...65 2N TELEKOMUNIKACE a s www 2n cz 3 6 Downloads Templates Nametags...