26
Programming Example:
Sets the GSM Gateway clock at 12 o’clock, 30 minutes, 0 seconds.
Important warning!!!
While setting time parameters note the units they are
set in – seconds or milliseconds. Since you cannot enter the decimal point
from your telephone, milliseconds must be used wherever seconds are too
rough. However, you cannot enter any number in the allowed interval
(173
ms, e.g.), but you have to respect the
step
prescribed for the particular
parameter. If one step is 100 ms, e.g., your value must end with two zeroes.
Example:
Parameter 243, tariff pulse length, has a step of 10 ms. Hence you cannot enter 66 ms, e.g., but
70 ms. To set 1 second, you have to enter 1000.
5.3.4. Programming of Multi-Parameter Line Tables
Some parameters constitute a two-dimension table (the Call Sorting Table, e.g.). In the
table, one line has a three-digit number and can contain up to 10 parameters. The
individual parameters on the line have a four-digit number, differing in the last digit. They
can be entered as follows:
•
Each parameter separately:
follow the preceding procedure, but use a four-digit
parameter number;
•
More parameters in sequence:
this method is quicker and is as follows:
1) First enter a three-digit number of the parameter line.
2) After the number and
are entered, the GSM Gateway sends a confirmation signal
if such parameter line exists and is available in the particular model and software
version. If it is not available, the GSM Gateway transmits a rejection signal
.
3) Then enter the first parameter and
. The GSM Gateway transmits a storing signal
2
if the parameter is in the allowed interval. This signal is different from the
common storing signal
(refer to the
Signalling During Programming Table
) and
indicates that the value has been stored and the following parameter is awaited.
4) The programmed value is stored immediately during transmission of the storing
signal 2
or
.
5) Then, you can enter the next parameter and
. The procedure is the same.
6) To signal that this was the last parameter to be programmed, press
and
.
7) The remaining parameters on the line will not be changed.
8) If you enter all parameters, the GSM Gateway transmits a common storing signal
after the last one.
9) Therefore, you cannot pass onto the next line by simply entering parameters; you
have to enter the line number.
10) To program a table line in the above-described way, you always have to start with the
first parameter.
Example:
Stores the first 3 parameters into line 501 (to be specific, the 0602 prefix is allowed and the call
will not be stored in the buffer).