1.
2.
3.
4.
5.
6.
7.
Cut a hole 100 (W) × 180 (H) mm.
Unscrew the front panel from the door intercom.
Connect the cables in the hole to the terminals or RJ connector as described in
the
.
Electric Connection subsection
Mounting completion – after electric
installation!
Insert the intercom in the hole keeping it in the vertical position.
Loosen the four clamp screws one after another and then retighten them slowly.
They will turn aside automatically and start moving forwards in their slots. You
need about
to tighten the clamps completely. You can perfect the
10 turns
vertical position before final tightening of the screws.
We do not recommend you to insert the button tags now.
Replace the stainless steel front panel fixing it with the stainless steel screws you
unscrewed in step 2.
Caution
Check the plasterboard wall and room interior pressure values (caused, e.
g., by overpressure ventilation). If the difference between the values is
too great, separate the intercom using, for example, the mounting box
enclosed and seal the cable passage to avoid loudspeaker damage.