Resetting Procedure – Display Model (models with 535v1 and 535v2 board versions)
To reset the default values of a display-
equipped
2N
®
IP
Vario
, put the switch in the display
right-hand bottom corner in position F_RES. This applies to modules with board versions 535v1
and 535v2 only. For 535v5 versions, use a jumper at connector X13.
Reset Button
Located among the main unit connectors, the Reset button helps you reset the factory default
values, restart the device, find the device IP address and switch the static/dynamic mode.
IP Address Finding
Follow the instructions below
to
identify the
current IP address
:
Press and hold the RESET button.
Wait until the red and green LEDs go on simultaneously on the device and the acoustic
signal
can be heard (approx. 15–35 s).
Release the RESET button.
The device automatically announces the current IP address.