58
2N TELEKOMUNIKACE a.s., www.2n.cz
Switch Control
The switches if available can be used during outgoing and incoming calls. Activate the
switch with a preset password in the following format:
password
of the
maximum length of 16 digits.
confirms switch activation and closes the
2N Lift1
®
switch for a preset time (1 to 10 seconds) sending a tone signal (see the signalling
table). The call is terminated in 30 seconds after the switch activation time.
2N Lift1 Signalling
®
2N Lift1
®
uses various signals to communicate with the operating staff during
programming. Refer to the table below for a list of these signals:
Signal
Name
Meaning
Confirmation
The signal is sent to the line (for the calling user)
when the incoming call is answered.
Remote switch activation.
Rejection
This signal is sent when a non-programmed button is
pressed.
When the communicator gets connected to the line,
the connection signal is heard from the speaker.
This tone is sent instead of confirmation in incoming
calls to signal that
is not configured or
2N Lift1
®
memory data are corrupted.
Saving
End of remote switch activation
Hang-up
This signal is sent just before the call end (in all the
cases).
Long continuous
tone
Deletion
The tone is sent to signal dialling memory deletion,
full initialisation and memory deletion before user
message recording.
"Attention, the
call is ending"
This announcement is sent during outgoing/incoming
calls to signal that the maximum call time will expire
in 10 seconds.
"Wait please ..."
Optional announcement during call setup
"Communicator
number ... is
calling"
Optional lift identifying announcement
Voice menu
In the programming mode
Tip
Use the switch for lift reset, for example. Control each switch with up to
10 passwords. You can also leave out the asterisks if the password begins
with 7 to 9 or 0 (this applies to the Automatic dialling with confirmation
mode).