Installation Manual 2N® IP Style
63
/
88
•
•
•
•
•
•
•
ID or PIN code. All the inputs and outputs are galvanically isolated from the
2N
®
IP Verso
system
with insulation strength of 500 V DC.
The module contains two VBUS connectors for device bus connection.
These two connectors are interchangeable and can be used either as inputs from the basic
unit or outputs to other modules.
If this module is the last one on the bus, one of the connectors remains unconnected.
The module package includes a 80 mm long interconnecting cable.
The module also includes:
Isolated OSDP bus
Power and pairing mode signaling LED
Tamper switch (9155038) input
Installation Procedure
Having connected the
OSDP module
to
2N
®
IP Verso
via the VBUS, connect the OSDP device to
the module. The
OSDP module
uses the RS-485 bus for the interface.
Connect the OSDP device as instructed (A to B or B to A) keeping the correct order to avoid
malfunction.