7.6.3. VoIP Board Configuration (Web Interface)
While configuring the system using the web interface keep the default values of the following
parameters.
Trunk configuration:
Protocol type =
E1 TRANSPARENT 30
Clock master =
Recovered
Framing metod =
SUPERFRAME
Line code =
HDB3
Control protocol configuration:
Control protocol type =
MGCP
Call agent IP = IP address of CPU card (default 10.1.10.15)
Call agent port =
5060
Profile =
NORMAL
!!! PLEASE MAKE CHANGE ONLY IP CONFIGURATION PARAMETERS AND CALL AGENT
IP ADDRESS. CHANGING THE OTHERS PARAMETERS MAY CAUSE BAD FUNCTION OF