![2N Telekomunikace 2N BlueStar User Manual Download Page 36](http://html.mh-extra.com/html/2n-telekomunikace/2n-bluestar/2n-bluestar_user-manual_439966036.webp)
34
established, please recheck the right configuration of PRIGW and your router/PBX.
For actual status of PRI interface please open item in top menu Gateway Control,
Diagnostics and select PRI.
Description of this window you find on pages 53, section 9.4.3.
6/ Section G
ATEWAY CONFIGURATION
,
GSM
GROUPS ASSIGMENT
(description on page 71, section
9.7.4.2)
-
Divide the GSM modules (cards) to outgoing and incoming GSM groups according to
you installation requirements
7/ Section G
ATEWAY CONFIGURATION
,
GSM
OUGOING GROUPS
(description on page 72 section
9.7.4.3)
-
for first start select parameter Mode of switching SIM card and last searched SIM to
SIM1 for each GSM group which you are using
8/ Section G
ATEWAY CONFIGURATION
,
P
REFIXES
(description on page
Chyba! Záložka není
definována.
section
Chyba! Nenalezen zdroj odkaz
ů
.
)
-
in case that you using more GSM operator please make delete of all eight Prefix lists
and add to Prefix list 1 prefixes for GSM operator 1, to Network list 2 for GSM
operator 2 etc… Please don’t remember to add also right length of dialed number for
each prefix.
9/ Section G
ATEWAY CONFIGURATION
,
LCR
TABLE
(description on page 78 section 9.7.5)
-
here you have possibility set in which time which prefixes (saved in prefix lists) will be
routed to which GSM group. You can select more GSM groups in one line – gateway
will try use second GSM group in case that first GSM group is not available or busy.
Also you can set more tries for one GSM group > for increase ASR…
10/ In top menu in G
ATEWAY CONTROL
, open item
DATE
/
TIME
for set right time and date in the
gateway
11/ In top menu in G
ATEWAY CONTROL
, open item L
OGIN ACCOUNT
to change access rights for
remote control via Telnet or PRI ISDN
12/ Save the configuration to PRIGW
13/ Plug-in the SIM cards and connect antennas and make restart of the gateway.
In case that you have problem with right function please read carefully this manual, check all
parameters. Also you can contact us by e-mail
. To email please write detail
description of problem and also attach the configuration file of the gateway (unnamed.ini)