51
2N TELEKOMUNIKACE a.s., www.2n.cz
2.4 Připojení rozšiřujících modulů
2N
®
Access Unit
allows to connect following extending modules:
Infopanel
Klávesnice
125kHz RFID card reader
13.56MHz RFID card reader
I/O modul
Electronic buttons
Wiegand modul
Security relay
Module Bus Interconnection
All the modules that can be connected to
are interconnected via a
2N
®
Access Unit
bus. The bus starts on the basic unit and goes over all the modules. The order of
modules on the bus is irrelevant. And it also irrelevant which bus connector on the
module is used as the input and which is used as the output.
The modules include a 220 mm long bus interconnecting cable;
Wie
Part No. 9155037
gand modules and
I/O modules include an 80 mm long bus cable.
Part No. 9155034
You can order a separate 1 m long bus cable (
,
,
Part Nos. 9155050 9155054
) of the length of 1 m, 3 m or 5 m for remote module installation. Typically, it
9155055
helps install an RFID card reader on the opposite side of the wall on which the
2N
®
is installed. This long cable can only be used once on the bus.
Access Unit
The modules can be combined in each base as follows:
Module
Externally mounted
(visible module)
Internally mounted
(invisible module)
X
Klávesnice
X
125kHz RFID card reader
X
13.56MHz RFID card reader
X
I/O modul
X
Wiegand modul
X
Module Power Supply
All the modules connected to
, except for the Tamper Switch, are
2N
®
Access Unit
powered from the bus. The available bus power output depends on the power supply
type. The basic unit can use a 2A power supply to increase the bus power available to
the modules connected.
Power supply
Specification
Available power output
External supply
12 V ±15% / 2 A (3 A)
24 W (36 W)
PoE
802.3af (Class 0 – 12.95 W)
12 W
Combined
External PoE
30 W (42 W)
The count of modules on the bus is limited by the available power supply output. The
maximum count of the modules on the bus is 30.
Summary of Contents for 2N Access Unit 916009
Page 1: ...www 2n cz Version 2N Access Unit Access Control Installation Manual 2 2 ...
Page 28: ...28 2N TELEKOMUNIKACE a s www 2n cz Flush mounting plasterboard ...
Page 29: ...29 2N TELEKOMUNIKACE a s www 2n cz ...
Page 30: ...30 2N TELEKOMUNIKACE a s www 2n cz Module flush mounting ...
Page 31: ...31 2N TELEKOMUNIKACE a s www 2n cz ...
Page 32: ...32 2N TELEKOMUNIKACE a s www 2n cz Wall surface mounting ...
Page 33: ...33 2N TELEKOMUNIKACE a s www 2n cz ...
Page 34: ...34 2N TELEKOMUNIKACE a s www 2n cz ...
Page 35: ...35 2N TELEKOMUNIKACE a s www 2n cz 2 2 2 Krabice pro dva moduly Flush mounting classic bricks ...
Page 36: ...36 2N TELEKOMUNIKACE a s www 2n cz ...
Page 37: ...37 2N TELEKOMUNIKACE a s www 2n cz Flush mounting plasterboard ...
Page 38: ...38 2N TELEKOMUNIKACE a s www 2n cz Module flush mounting ...
Page 39: ...39 2N TELEKOMUNIKACE a s www 2n cz ...
Page 40: ...40 2N TELEKOMUNIKACE a s www 2n cz ...
Page 41: ...41 2N TELEKOMUNIKACE a s www 2n cz ...
Page 42: ...42 2N TELEKOMUNIKACE a s www 2n cz Wall surface mounting ...
Page 43: ...43 2N TELEKOMUNIKACE a s www 2n cz ...
Page 44: ...44 2N TELEKOMUNIKACE a s www 2n cz ...
Page 58: ...58 2N TELEKOMUNIKACE a s www 2n cz Connection ...