User Code Setup
In the DT system, every apartment must have a unique identification called User Code. The DIP switches are used to
configure the User Code for each Monitor.
• Bit -1 to Bit -5 are used to User Code setting. The value is from 1 to 32, which have 32 different codes for 32
apartments.
• When multi Monitors are installed in one apartment, these Monitors have to use the same User Code setting,
and the Master/Slave mode should be set on the Monitor.
• Bit -6 is line terminal switch, which have to be set to ON if the Monitor is in the end of the line(bus), otherwise set
to OFF. The end of the line is terminal that no other section will start from it.
ON(1)
=
OFF(0)
=
ON
ON
ON
1 2 3 4 5 6
Bit state
User Code
Bit state
User Code
Bit state
User Code
1 2
3 4 5
6
ON
Code=1
1 2
3 4 5
6
ON
Code=12
1 2
3 4 5
6
ON
Code=23
1 2
3 4 5
6
ON
Code=2
1 2
3 4 5
6
ON
Code=13
1 2
3 4 5
6
ON
Code=24
1 2
3 4 5
6
ON
Code=3
1 2
3 4 5
6
ON
Code=14
1 2
3 4 5
6
ON
Code=25
1 2
3 4 5
6
ON
Code=4
1 2
3 4 5
6
ON
Code=15
1 2
3 4 5
6
ON
Code=26
1 2
3 4 5
6
ON
Code=5
1 2
3 4 5
6
ON
Code=16
1 2
3 4 5
6
ON
Code=27
1 2
3 4 5
6
ON
Code=6
1 2
3 4 5
6
ON
Code=17
1 2
3 4 5
6
ON
Code=28
1 2
3 4 5
6
ON
Code=7
1 2
3 4 5
6
ON
Code=18
1 2
3 4 5
6
ON
Code=29
1 2
3 4 5
6
ON
Code=8
1 2
3 4 5
6
ON
Code=19
1 2
3 4 5
6
ON
Code=30
1 2
3 4 5
6
ON
Code=9
1 2
3 4 5
6
ON
Code=20
1 2
3 4 5
6
ON
Code=31
1 2
3 4 5
6
ON
Code=10
1 2
3 4 5
6
ON
Code=21
1 2
3 4 5
6
ON
Code=32
1 2
3 4 5
6
ON
Code=11
1 2
3 4 5
6
ON
Code=22
Bit -6 line terminal setting:
Bit state
Setting
Bit state
Setting
1 2 3 4 5
6
ON
Monitor not at
the end of the
line.
1 2 3 4 5
6
ON
Monitor at
the end of
the line.