1. Preface

We would like to congratulate you on the purchase of our pressure switch. We appreciate your trust. That's why functional 
security and                                                                        
perational

 

safety stands by us on first place.

2. Universal

Flow guard is designed to automatize the starting and stopping operations of an electric pump with regard to a drop in pressure 
(open Ing of the taps) and to the stopping of the flow through the system (closing of the taps) respectively. Furthermore, Flow 
guard stops the pump when senses the lack of waterftow, preventing it from any damaging dry operation.
lt is advisable using Flow guard with water systems whose water is without sediments. In case it is not possible, it is necessary 
to install a filter before the inlet of the device.
The pressure gauge indicates the starting pressure value and the pressure in the system.
Furthermore it helps to verifiy any possible presence of water leakages in the system.

PLEASE READ THIS INSTRUCTION LEAFLET CAREFULLV THROUGH BEFORE INSTALLING AND 
PERATING THE DEVICE

3. Installation

Install Flow guard anywhere between the pump and the first service outlet. Make sure that device is mounted in  
correct flow direction (some devices have the arrows moulded on the case). Check perfect water tightness of all water  
connections. If you are using a pump with a pressure higher than 10 Bar,install a pressure reducer on the Flow guard 
inlet.

For the electrical connection of the version supplied without electric leads,follow the wiring diagram on the printed  
circuit board cover, or on the drawing (page 7) following. Furthermore, in case of use of a pump with power higher  
than 1/2 HP and the ambient temperature is higher than 25°C it is necessary to wire pressure switch with cables with a 
thermic resistance not inferior to 99 °C. Use only suitable wire nippers to wire the device. If the Cables are included,  
simply connect the pumps power plug to the pressure switch socket and its own power plug to a current outlet.

Operating pressure is pre-set at 1.5 bar which is the optimum value for the majority of applications. Minimum  
operation pressure can be adjusted as needed by turning the screw situated on top of the device, it's marked with+ 
and-.

The height of the water column above the Flow guard should not be more than 15m.

ATTENTION: The check valve installed in the pump outlet and in the 

Flow guard

 inlet can cause some anomalies during the 

normal working of 

Flow guard. 

Therefore its advisable avoiding its installation between the pump and pressure switch

4. Operation Instructions

WARNING: whenever the level of the priming water is lower than the level of the water where the pump is placed, a suction 
line equipped with an anti backflow foot value is absolutely essential. This value allows the line to be filled when it is first used 
and prevents it from being emptied when the pump stops.

Before first use, fill the pump and the suction pipe with water. Please make sure that all connection are watertight.

Connecting the electric to the pump (page 7.)

Open the tap.

Connecting the pressure switch to power line.

Wait until water runs out of the tap, than close it.

After 10-15 sec. the device will switch of the power of the pump.

Please make sure again that all connection are watertight.

Installation is correct if the flow from the tap is regular and if the pump works continuously without clocking, and 
stop working after reaching the chosen pressure value. Please repeat the test a couple of times.

Dry stop: The red FAILURE LED lights up with motor off to indicate a dry stop. To start the system again press the RESET 
button after having checked the presence of water in the suction pipe .

Attention! Don't install a back-pressure valve between pump and switch!

ENGLISH

5

Summary of Contents for AQUA-21

Page 1: ...PRESSCONTROL FLOW GUARD DURCHFLUSSWÄCHTER INSTRUCTION MANUAL BEDIENUNGSANLEITUNG AQUA 21 Automatic Controller PS01109 ...

Page 2: ...ung 2 5 Sicherheitshinweise 3 6 Wartung 3 7 Gesetzliche Gewährleistung 3 8 Erkennen und Beheben von Fehlern 3 9 Technische Daten 7 10 Elektrischer Anschlussplan 7 Impressum 1A Profi Handels GmbH www profi pumpe de Email info 1a profi handel de Tel 49 0611 945877600 Fax 49 0611 9458776911 DEUTSCH 1 ...

Page 3: ...teckdose des Stromnetzes anzuschließen 3 Der Druck bei dem das AC 21 Gerät einschaltet ist auf 1 5 bar voreingestellt dieser Druck ist für die meisten Anwendungen optimal Er kann durch einen Fachmann mittels der Einstellschraube am oberen Ende verändert werden 4 Die Höhe der Wassersäule über dem AC 21 sollte nicht über 15m betragen ACHTUNG FÜR EINEN KORREKTEN BETRIEB DES AC 21 MUSS DER MINDESTDRUC...

Page 4: ...stehen so dass die Pumpe unter keinen Umständen weiter betrieben werden darf Bis zum Geräteaustausch ist die Pumpe außer Betrieb zu setzen Folgende Kontrollen sollten regelmäßig durchgeführt werden Unversehrtheit des Stromkabels Saubere Führung der Leitungen z B keinen Knick Sauberkeit des Mediums 7 Gesetzliche Gewährleistung Für alle Fabrikations und Materialfehler gewähren wir die gesetzliche Ge...

Page 5: ...afety regulations 6 6 Servicing 6 7 Guarantee regulations 6 8 Recognising and repairing of mistakes 6 9 Technical data 7 10 Electric Installation 7 Impressum 1A Profi Handels GmbH www profi pumpe de Email info 1a profi handel de Tel 49 0611 945877600 Fax 49 0611 9458776911 ENGLISH 4 ...

Page 6: ...ior to 99 C Use only suitable wire nippers to wire the device If the Cables are included simply connect the pumps power plug to the pressure switch socket and its own power plug to a current outlet Operating pressure is pre set at 1 5 bar which is the optimum value for the majority of applications Minimum operation pressure can be adjusted as needed by turning the screw situated on top of the devi...

Page 7: ... dangerous The following controls should be carried out regularly Intactness of the electric cable That the connection hoses are not bent or broken Cleanness of the pump medium Moreover the pump should be emptied with risk of frost be washed out with clear water and stored dry 7 Guarantee regulations For all manufacturer defects and material defects we grant the statutory guarantee time new and un...

Page 8: ...sertemperatur 60 C Input connector Anschlüsse Eingang 2 54 cm 1 Output connector Anschlüsse Ausgang 2 54 cm 1 Protection grade Schutzart IP 65 10 Electric installation Elektrischer Anschluss Plan und Installationsschema 7 Technische Änderungen Druckfehler und Irrtümer vorbehalten L1 Power braun brown Phase N Power blau blue Null E Power grün_gelb green_yellow Erde E Pumpe grün_gelb green_yellow Er...