background image

1

SBP-1100e Features

•  External dimensions approx. 15” L x 11” W x 6 .5” H, including receptacles with carrying handle folded.
•  Fits within a space 16” L x 12” W x 7” H, but 12” additional length should be allowed for cable bends.
•  Integrated battery monitor panel reports condition and state-of-charge percentage.
•  Can be recharged more than 400 times, typically.
•  Durable, rugged, water resistant, and crush resistant case; airtight (with pressure relief valve)
•  100% depth of discharge allowed, versus 30% to 60% for lead-acid storage battery technologies.
•  Light weight — a third of the size and weight of comparable sealed lead acid packs with casing and venting.
•  Deep discharge WITHOUT damage, no urgency to re-charge.
•  Automatic shut-down at full discharge with preceding user notifications.
•  Rapid charging — 10 hrs to full charge from empty, using AC power adapter: 

SBP-AC-ADAPTER-24V-130W

•  Integrated battery pack protection circuitry for safety.
•  Partial charge/discharge cycles OK, no memory effects.
•  Cells do not out-gas, environmentally benign compared to lead or nickel-cadmium chemistries.

SBP-1100e Specifications

Standard Output Voltages (factory-set)

13.8 volts DC, +/- 4%, for nominal 12-volt applications, 25.3 volts DC, +/- 4%, for nominal 24-volt applications

Other Output Voltages (examples)

6, 9, 12.4, 16, 24, or 28 volts DC, +/-4 %, factory-set

Custom Output Voltages

Fixed voltages from 6 to 28 volts DC, +/- 4%, factory-set

Input (Charging) Voltage

10 to 28 volts DC, continuous (filtered or low-ripple) Use an approved power source

Input (Charging) Power

up to 200 watts, in increments of 50 watts.

Energy Storage Capacity (10 hr. discharge)

1100 watt-hours, initial capacity, 1000 watt-hours available for output

Amp-hour Storage Capacity (10 hr. discharge)

72 Amp-hours (13.8 volt model), 40 Amp-hours (25.3 volt model)

Temperature Range for charging

0˚to 40˚C (32 deg. F to 104 deg. F)

Temperature Range for discharging

-20˚to 50˚C (-4 deg. F to 122 deg. F)

Temperature Range for storage

-20˚to 60˚C (-4 deg. F to 140 deg. F)

Max. Continuous Discharge Load

(less than 1 hour, at 25 deg. C, 77 deg. F)

25.3 volts: 300 watts
13.8 volts: 280 watts
9 volts: 180 watts
6 volts: 120 watts

Max. Continuous Discharge Load

(more than 1 hour, at 25 deg. C, 77 deg. F)

25.3 volts: 200 watts 
13.8 volts: 180 watts
9 volts: 120 watts
6 volts: 80 watts

Charge/discharge Cycle Life

more than 400 cycles, typical (20% reduced capacity after 300 discharge cycles)

Service Life

about 5 years, typical, for 20% reduced capacity due to aging. Batteries age faster at higher storage temperatures and at higher 
storage state-of-charge.

Weight

approx. 28.5 lbs.

Recharge time from empty

8 to 10 hours, using the 130 watt SBP AC adapter (SBP-AC-ADAPTER-24V-130W). Consult 1100 Energy for other charging options

Output Noise and Ripple

100 mV peak-to-peak at maximum load, for 25.3 volts DC output.  Noise and ripple are proportionate to loading.

Power Input Receptacle

MS3112E14-5P, 5-pin contact male MIL receptacle, box mount

Power Input Mating Plug

MS3116F14-5S, 5-socket contact female MIL plug, cable-mount, with strain-relief clamp. (Plug is available from 1100 Energy as item 
no. SBP-CON-INPUT)

Power Output Receptacle

MS3112E14-5S, 5-socket contact female MIL receptacle, box mount

Power Output Mating Plug

MS3116F14-5P, 5-pin contact male MIL plug, cable-mount, with strain-relief clamp. (Plug is available from 1100 Energy as item no. 
SBP-CON-OUTPUT)

Serial Data Receptacle

MS3112E10-6P 6-pin contact male MIL receptacle, box mount

Serial Data Mating Plug

MS3116F10-6S 6-socket contact female MIL plug, cable-mount, with strain-relief clamp. (Plug is available from 1100 Energy as item 
no. SBP-CON-DATA)

Summary of Contents for SBP-1100e

Page 1: ...SBP 1100e Smart Battery Power System Software version 4 1 2 User Manual ...

Page 2: ...r damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjustm...

Page 3: ...harging Using DC power sources 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Power to a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port 5 Serial Data Port Connection Specifications 5 Control Panel Buttons 6 LCD Backlighting 6 LCD Panel Indications 6 Storage 8 Outdoor Use 8 Lithium Ion 8 Caution...

Page 4: ... SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to supplying power to the equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is...

Page 5: ...y 10 hr discharge 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load less than 1 hour at 25 deg C 77 deg F 25 3 volts 300 watts 13 8 volts 280 watts 9 volts 180 watts 6 vol...

Page 6: ...tate of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready ...

Page 7: ...solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made th...

Page 8: ...back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the ...

Page 9: ...a Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plu...

Page 10: ...CROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully charged The bar graph indication uses darkened blocks to represent f...

Page 11: ...rging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A ...

Page 12: ...s battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP...

Page 13: ...toring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energ...

Page 14: ...10 Eleven Hundred Energy Corporation ...

Page 15: ......

Page 16: ...12 Eleven Hundred Energy Corporation ...

Page 17: ... 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com ...

Reviews: