•  Recommended temperature range for storage: -20˚C (-4˚F) and 60˚C (140˚F) (store at low to moderate tempera-

tures to maximize battery life.). Storage at temperatures above 45˚C (113˚F) reduces battery life.

•  Prolonged storage periods: Store the SBP-1100e at 20% to 50% capacity and at low to moderate temperatures. 

Prolonged storage at a high state of charge will degrade the storage capacity of lithium-ion batteries.

Outdoor use

The SBP-1100e is weather-resistant and ruggedly packaged, but when used outdoors, it should not be left fully exposed 

to the weather, if it can be avoided. Direct sun can cause overheating, and prolonged exposure to sun, rain, snow, salt 

spray, dust and wind-blown debris may accelerate deterioration of the case and control panel. Some covering, such as a 

rain-shedding, sun-blocking tarp or lean-to should be provided, and the covering should allow for some natural circula-

tion of air around the SBP-1100e case during hot weather.
If the SBP-1100e is to be used in extremely hot or extremely cold outdoor environments, shallow burial of the unit in the 

earth will moderate the temperature extremes. Shallow burial might also be used as a means of hiding the SBP-1100e. 

Since the earth may tend to become saturated with water from time to time due to rain, some waterproof protective 

wrapping or bagging, and/or provision for drainage, may be desirable.

Lithium-Ion

Lithium-Ion packs, unlike Lead-Acid batteries, do not have to be fully charged before use. If charging is stopped prior to 

full charge, the SBP-1100e can be discharged without diminishing cycle life. In addition, unlike NiCd and NiMH batter-

ies, Li-Ion batteries can be recharged at any state-of-charge without degradation to the battery’s cycle life performance 

and without memory (voltage depression) problems.
The ideal usage pattern for lithium-ion batteries is to be charged and discharged on a daily to weekly cycle, as would be 

typical of a solar panel-based application. Prolonged storage at a high state of charge should be avoided, as it degrades 

battery capacity, but prolonged storage at a moderate or low state of charge (40% or less), or in a fully discharged state, 

is not harmful. All batteries, including lithium-ion batteries, will slowly self-discharge while in storage. After several 

months in storage, lithium-ion batteries may go dead, but the batteries can be readily brought back to life by applying a 

suitable ‘wake-up’ charging regimen. The SBP-1100e automatically applies the ‘wake-up’ charge regimen when appro-

priate, and when charging power is made available. The SBP-1100e should be ready for normal use after a couple of 

hours of ‘wake-up’ charging from a dead state, although it will take longer than two hours to reach full charge.
Lithium-ion batteries slowly degrade over time, whether or not they are being ‘used’ (charged and discharged) on a reg-

ular basis. Provided the batteries have not been subject to prolonged storage at a high state of charge, a typical useful 

service life might range from two to five years. Typically, the capacity rating will degrade by about 20% after about 300 

charge/discharge cycles. When degradation of the internal batteries reduces the energy storage capacity of the SBP-

1100e below a level which is suitable for the application, the SBP-1100e has reached the end of its service life. In some 

cases, an SBP-1100e unit may be returned to 1100 Energy, reloaded with new lithium-ion batteries, and refurbished for 

continued use. Contact 1100 Energy for details.

Cautions

• 

DO NOT open the battery pack case! Doing so may risk personal injury.

• 

DO NOT submerge battery pack in water.

• 

DO NOT use battery pack cables not specified as compatible by 1100 Energy.

• 

Charge the SBP-1100e at temperatures between 0° and 40° C. The discharge and storage temperature ranges are 

-20° C to 50° C and -20° C to 60° C, respectively.

• 

The SBP-1100e may present a risk of fire or chemical burn if mistreated. DO NOT short circuit, drop, crush, muti-

late, nail penetrate, reverse polarity, disassemble, or expose to temperatures above 100° C.

• 

Lithium-Ion batteries are Class 9 hazardous materials subject to transportation restrictions including commercial 

air transportation. Caution and planning should be exercised before transporting the SBP-1100e by common carrier 

ground transportation.

Standard Accessories ¹

Summary of Contents for SBP-1100e

Page 1: ...SBP 1100e Smart Battery Power System Software version 4 1 2 User Manual ...

Page 2: ...r damage that result from a Improper operation or storage misuse or abuse accident or neglect such as physical damage to the surface of the product resulting from misuse b Subjecting the product to abnormal usage or conditions c Other acts which are not the fault of 1100 Energy are excluded from coverage Unauthorized Service or Modification Defects or damages resulting from service testing adjustm...

Page 3: ...harging Using DC power sources 3 Battery Charging Using MF15 3600 Solar Panels 3 Power Input Connection Specifications 3 Supplying Power to a Load 4 Power Output On and Off Control 4 Power Output Connection Specifications 5 Serial Data Port 5 Serial Data Port Connection Specifications 5 Control Panel Buttons 6 LCD Backlighting 6 LCD Panel Indications 6 Storage 8 Outdoor Use 8 Lithium Ion 8 Caution...

Page 4: ... SBP continues to power the application equipment during solar charging and afterwards using the stored energy In using input power available to the SBP 1100e priority is given to supplying power to the equipment load and any additional input power which may be available is used to charge the internal batteries until the batteries are fully charged So long as some stored energy in the SBP 1100e is...

Page 5: ...y 10 hr discharge 72 Amp hours 13 8 volt model 40 Amp hours 25 3 volt model Temperature Range for charging 0 to 40 C 32 deg F to 104 deg F Temperature Range for discharging 20 to 50 C 4 deg F to 122 deg F Temperature Range for storage 20 to 60 C 4 deg F to 140 deg F Max Continuous Discharge Load less than 1 hour at 25 deg C 77 deg F 25 3 volts 300 watts 13 8 volts 280 watts 9 volts 180 watts 6 vol...

Page 6: ...tate of charge from 40 to 49 The operational mode will appear on the bottom line of the LCD display unless the unit is charging in which case Charging will appear If the mode is Idle the unit is ready for use If the mode is Twilight connect a charging power source as described above and allow the unit to charge at least until the state of charge reaches about 15 To check whether the unit is ready ...

Page 7: ...solar panels to the cables should be tightly mated to keep out rain water and all the connectors should be kept out of rain puddles if possible Any unmated connectors should have the rubber safety caps which are tethered to them installed securely onto the connectors to protect from rain water Avoid using the connectors near hazardous voltages When the cable and panel connections have been made th...

Page 8: ...back to life within 3 seconds after external power is applied and after a suitable period of charging the SBP 1100e battery pack may again be used normally In the event that charging power is applied after the output has been cut off the state of charge must rise to about 15 before the output will be turned on again Power Output On and Off Control To check the output voltage and current press the ...

Page 9: ...a Port Connection Specifications Note Fully assembled 10 foot SBP CBL RS232 10FT or 5 foot SBP CBL RS232 5FT RS 232 Data Cables are avail able from 1100 Energy The cables will connect the SBP 1100e directly to a 9 pin serial port of a personal computer Mating Plug Model SBP CON DATA Serial Data Port mating plug miniature cylindrical 5 pin female for SBP 1100e MIL C 26482 Series 1 shell size 10 plu...

Page 10: ...CROLL button There is space for two lines of text or graphics on the display and when the SCROLL button is pressed the top line will display the present charge state in two formats the numerical percentage and a horizontal bar graph The per centage indicated is the relative state of charge between 0 fully discharged and 100 fully charged The bar graph indication uses darkened blocks to represent f...

Page 11: ...rging and is not powering a load and thus is said to be idle Idle In the example below the unit is both charging or discharging that is some internal batteries are being charged while others are being discharged Dschrge Charge In the example below the input voltage and input current are displayed In 23 5V 3 2A In the example below the output voltage and output current are displayed Out 13 8V 4 3A ...

Page 12: ...s battery capacity but prolonged storage at a moderate or low state of charge 40 or less or in a fully discharged state is not harmful All batteries including lithium ion batteries will slowly self discharge while in storage After several months in storage lithium ion batteries may go dead but the batteries can be readily brought back to life by applying a suitable wake up charging regimen The SBP...

Page 13: ...toring purposes To see a list of accessories please visit our website at www 1100energy com or contact us Disposal At end of life please contact 1100 Energy for advice concerning disposal or recycling including options for returning the unit for refurbishing and renewal of the internal batteries Keep away from children Do not disassemble and do not dispose of in fire Contact information 1100 Energ...

Page 14: ...10 Eleven Hundred Energy Corporation ...

Page 15: ......

Page 16: ...12 Eleven Hundred Energy Corporation ...

Page 17: ... 2010 1100 Energy Corportion 2145 Priest Bridge Drive Crofton MD 21114 410 721 9032 sales 1100energy com www 1100energy com ...

Reviews: