Appendix A Parameter List
A.1 System Management
ETERNUS Web GUI User’s Guide (Settings)
Copyright 2015 FUJITSU LIMITED
P2X0-1270-13ENZ0
736
•
NAS Quota Limit Exceeded
•
Virus Scan Server Connection Error
•
Virus Pattern File Warning
•
Virus Scan Engine Warning
•
Virus Scan License Warning
•
Out of Virus Detection Log Space
Description
Select whether to notify when the Quota configuration information (Drive Used Size or
File Count) for users or groups exceeds the threshold in the NAS system. When notifying,
select the notification method.
This item is only displayed in a Unified Storage environment.
•
The relevant event is notified when both the warning and limit values are specified and the status changes as
described below.
-
Less than the warning value
Exceeds the warning value
-
Less than the warning value
Exceeds the limit value
-
More than the warning value and less than the limit value
Exceeds the limit value
•
The relevant event is notified when only the limit value is specified and the status changes as described below.
-
Less than the limit value
Exceeds the limit value
•
The relevant event is notified when only the warning value is specified and the status changes as described
below.
-
Less than the warning value
Exceeds the warning value
Description
Select whether to notify when a communication error with the virus scan server is
detected in the NAS system. When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description
Select whether to notify if the virus scan pattern file is not up-to-date in the NAS system.
When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description
Select whether to notify if the virus scan engine is not up-to-date in the NAS system.
When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description
Select whether to notify if the virus scan server license in the NAS system expires within
30 days. When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.
Description
Select whether to notify when a system volume area for storing the virus detection log
becomes insufficient in the NAS system. When notifying, select the notification method.
This item is only displayed in a Unified Storage environment.