ZyWALL 1 Internet Security Gateway
5
POWER 5VDC Port
Use only the included 5 VDC power adapter or one with the
same specifications.
Connect the female end of the power adapter to the port labeled
POWER
5VDC
on the rear panel of your ZyWALL.
Additional Installation Requirements
1.
A computer(s) with an installed Ethernet NIC (Network Interface Card).
2.
A cable/xDSL modem and an ISP account.
Turning on Your ZyWALL
Plug the male end of the power adapter into a power outlet. The
SYS
LED turns
on. The WAN and the LAN LED(s) turn on after the system tests are complete,
if the WAN and LAN ports are properly connected.
RESET Button
If you forget your password or cannot access the ZyWALL, use the
RESET
button on the rear panel of the ZyWALL to reinstall the factory default
configuration (rom) file. Uploading the factory default configuration file
replaces the current configuration file with the default configuration file and
deletes all customer-made ZyWALL configurations. The Password resets to
“1234” and the IP address resets to 192.168.1.1.
Using the RESET Button
1.
Use a pointed object to press the
RESET
button for five seconds, then
release it.
2.
If the LAN LEDs flash within 30 seconds, the factory defaults have been
restored and the ZyWALL restarts. Otherwise, go to step 3.
3.
Turn the ZyWALL off.
4.
While pressing the
RESET
button, turn the ZyWALL on.
5.
Continue to hold the
RESET
button for about 30 seconds. The ZyWALL
restarts.
6.
Release the
RESET
button and wait about ten seconds for the ZyWALL to
finish restarting.