Accessing Piston Kit

1. 

Turn off water supply and press manual override button to relieve 

all water pressure.

2. 

Remove valve cap to expose ring insert.  Using the M3 Allen 

Wrench remove the 4 screws and the ring insert.

3. 

Remove the remaining 2 screws and the solenoid flange.

4. Remove the piston kit from the valve body and inspect for 

damage to the seals or debris in the orifice.  Excessive build up 

of debris may occur on filter screen.

• 

Do not use any abrasive or chemical cleaners to clean the flushometer.

•  ONLY use mildly warm soapy water, and then wipe the device dry with a clean/soft towel or cloth.

•  Upon cleaning other areas of the restroom, be sure the sensor lenses are protected from other cleaning chemicals/solvents to 

prevent potential damages to the sensor and/or electronics.

Cup Seal

Face Seal

Orifice

Filter

Screen

Care and Cleaning Instruction

Gateway Instruction

You can request your Ethernet or LTE gateway by visiting 

Zurn.com/plumbsmart-gateway-request

or call Zurn Customer Care at 1-844-987-6737

Step 1. Request Gateway:

Step 2. Cabling, Powering and Connecting Your Device:

1. 

Connect one end of the RJ45 Ethernet cable (supplied) to the 

gateway’s Ethernet port and plug the cable’s other end into the 

nearest wall port of the building’s Ethernet network.

2. 

Connect the power supply to the power jack.

3. 

Wait for status LED to go from ON to double flash every second, 

the LoRa LED to turn ON solid, and the cell LED (if LTE enabled) 

to flash once every 3 seconds. Should take around 1-2 minutes 

depending on location. Your gateway is now ready to transmit 

data from your Zurn connected product.

4. Zurn Gateways have been set to DHCP by default. Please 

consult  local  IT  support  for  possible  additional  access 

requirements for your network.

Step 3. Determining general Location for the Zurn Gateway:

•  Select a location central to all devices to be connected to this 

gateway. Place the gateway as high as possible, such as near 

the top of a wall.

• 

Avoid  obstructions. Thick  walls  and  reflective  surfaces,  such 

as metal, weaken the signal between the gateway and other 

devices.

•  The LoRa antenna is an omni-directional antenna, but for best 

results, mount the device so the LoRa antenna is in a vertical 

position near the top of a wall. We recommend conducting a site 

survey to test the signal strength in different locations before 

you mount the device.

Step 4. Mounting the Zurn Gateway:

The device ships with a mounting bracket. You will also need:

•  Four #6 screws with anchors 
•  Screwdriver 
•  Drill

1. Determine where you want to mount the device.
2. Mark where you want the screws to go.
3. Drill holes for the screws and insert anchors.
4. Place the mounting bracket and secure it with screws.
5. Attach the device to the bracket and rotate to lock into place.

Register in plumbSMART

NOTE:  Instructions below are duplicated from registration card supplied with monitor

1. 

Install Zurn Connected Product(s)

2. 

Install Zurn Gateway per the Gateway Instructions Manual

3. 

Request plumbSMART Administrator Account at 844-987-6737

4. 

Zurn creates your Enterprise Account for you! (You will be required to identify your building location, number of floors, and number 

of rooms.)

5.  Log in to plumbsmart.zurn.com

6. 

Register each Connected Product in plumbSMART (Watch How-To Videos to Get Started. Located in the support section inside the 

portal.)

7.  Now, Relax.  You’re Connected.

Содержание plumb smart AquaSense ZTR -W2 Series

Страница 1: ...xclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer prod...

Страница 2: ...pud Flush Connection Vacuum Breaker Vacuum Breaker Tube Cast Wall Escutcheon Vandal Cover Stop Valve Sweat Kit Valve Assembly Magic Magnet Batteries Spud Flush Connection Vacuum Breaker Vacuum Breaker Tube Cast Wall Escutcheon Vandal Cover Stop Valve Sweat Kit Batteries 3 32 5 64 Allen Wrench Flat Head Screwdriver Smooth Jawed Wrench ...

Страница 3: ...or high use applications where durability and hands free operation are necessary ADA compliant battery powered sensor operated for retrofit and new construction Unit is furnished with a clog resistant piston and manual override button Standard batter powered is 4 AA batteries with a 3 year life Long life battery powered is 4 AA batteries with a 10 year life NOTE The information in this manual is s...

Страница 4: ...th items over water supply pipe Press wall escutcheon flush against finished wall and tighten set screw with hex wrench supplied to secure it in place Using a flat head screwdriver turning counterclockwise flush supply line by opening the control stop Turning clockwise will close the control stop 2 Gallon 1 Install control stop assembly by threading it onto water supply pipe and tightening with a ...

Страница 5: ...Determine the length of vacuum breaker tube required to join the flush valve and fixture spud and cut if necessary Slide the tube nut spud nut slip gasket rubber gasket and spud escutcheon over the vacuum breaker tube and insert tube into fixture spud Hand tighten tube nut to valve body and hand tighten spud nut onto fixture spud Adjust the valve assembly for plumb Tighten fixture spud nut vacuum ...

Страница 6: ...solenoid connectors Battery Installation Instructions 2 Loosen and remove the 4 mounting screws from the back of monitor housing and remove back panel Install supplied batteries and reinstall back panel onto monitor housing Tighten mounting screw Only use one battery type for installation DO NOT mix and match Standard Alkaline and Long Life Lithium Batteries 1 Use the 3 32 Allen Wrench to loosen t...

Страница 7: ...econds to release any residual pressure 3 Use a 5 64 allen wrench to remove the two cap screws from the sensor cap and remove the sensor cap Disconnect black solenoid plug shown below Connected Sensor Cap Retrofit Installation Instructions 4 Remove the 4 sockets screws shown using a M3 allen wrench and discard the screws Solenoid connecting wire Right hand Orientation Left hand Orientation Remove ...

Страница 8: ... Tighten screws in the torque sequence shown on Figure on Tightening squence Then Follow steps 2 3 from Battery installation Instructions Section 1 3 4 2 Tightening Sequence 7 Align set screw hole in sensor cap with key way in ring insert and place sensor cap on valve body Rotate sensor cap counter clockwise until the set screw is visible in the sensor cap hole and the sensor is facing forward Usi...

Страница 9: ...ith the dual flush option Regular single flush valves will not function in dual flush mode 1 2 3 4 5 6 7 ON OFF STEP 1 1 Place the Zurn MagicMagnet supplied against the cap at the lower right corner of the Zurn logo under the sensor lens Hold in place until the valve automatically flushes and the red LED light flashes two 2 times Remove Magic Magnet from flush valve The valve has entered calibrate...

Страница 10: ...to transmit data from your Zurn connected product 4 Zurn Gateways have been set to DHCP by default Please consult local IT support for possible additional access requirements for your network Step 3 Determining general Location for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top of a wall Avoid obs...

Страница 11: ...ater pressure Piston and or solenoid plugged or damaged Remove Piston and or Solenoid to examine for damage or plugging Clean piston solenoid orifice if plugged Replace solenoid kit if solenoid diaphragm is damaged Low or no power allowing solenoid to move to open position but not enough power to return to closed position Replace batteries or restore power if hardwired MOB mechanical override butt...

Страница 12: ...R sensor and Faucet actuator electronics Restore proper electrical connection as needed Step 2 Test activate the faucet If problem persists see Faucet Troubleshooting section in this guide for other steps Status Good posted in plumbSMART and faucet actuates but usage event data not appearing in plumbSMART Charts Step 1 Verify gateway is powered and LoRa Status LED is ON If not apply power per Zurn...

Страница 13: ...acility IT administrator to modify port rules to allow Zurn gateway to access the internet via local router If gateway model is ETH LTE visually verify SIM card is installed in designated slot on the side of gateway If unit has a SIM card then disconnect ethernet cable and power cycle the gateway and wait for unit to initialize and connect LORA LED should turn ON solid after initialization Step 4 ...

Страница 14: ...t fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn Custom Service at 1 855 ONE ZURN 1 855 663 9876 for assistance High Daily Flush Rate posted in plumbSMART Step 1 Verify flush valve is not falsely triggering See Flush valve Troubleshooting section for appropriate di...

Страница 15: ...125 W2 PTR6200 L 0 25 W2 PTR6200 L 0 5 W2 PTR6200 L 1 0 W2 PTR6200 L 1 1 W2 PTR6200 L 1 28 W2 PTR6200 L 1 6 W2 PTR6200 L DF W2 Valve and Components Product No Valve Housing Items 8 9 PTR6200 HSA Solenoid Replacement Kit for Valves with Metal Caps Item 5 PTR6200 M Piston Kit 1 1 1 28 1 6 GPF Item 7 PTR6200 EC Piston Kit 0 5 1 0 GPF Item 7 PTR6203 EU Piston Kit 0 125 0 25 GPF Item 7 PTR6203 EU ULF M...

Страница 16: ...A 27330 Ph 1 800 997 3876 Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 07 23 20 C N No 142771 Prod Dwg No FV722 US 1 855 ONE ZURN CANADA 1 905 405 8272 ZURN COM ...

Отзывы: