background image

ZURN INDUSTRIES, LLC 

5900 Elwin Buchanan Drive, Sanford, NC U.S.A. 27330, Ph. 1-800-997-3876, Fax 919-775-3541

In Canada: 

ZURN INDUSTRIES LIMITED 

7900 Goreway Drive, Unit 10, Brampton, Ontario L6T 5W6, Ph. 905-405-8272, Fax 905-405-1292

Rev. C 

Date: 10/18/2018 

C.N. No. SAN008373 

Prod. | Dwg. No. CF1551

PAGE 3 OF 4

REPLACEMENT PARTS

SINGLE CONTROL HANDLE ASSEMBLY   

 

G63237

MOUNTING COMPONENTS FOR SINGLE CONTROL 

G65302

CERAMIC 

MIXING 

CARTRIDGE 

   63233001

8” 

COVER 

PLATE     G65505

HOSE 

SPRAY 

AND 

HOLDER 

   G67903

Trouble Shooting Guide

Problem Cause 

Solution

FAUCET LEAKS FROM

UNDER FAUCET 

HANDLE. ALL 

SUPPLIES ARE ON.

REMOVE FAUCET HANDLE . TIGHTEN 

CARTRIDGE RETAINING NUT. DO NOT 

OVER TIGHTEN. TIGHTEN UNTIL NUT IS 

SNUG

CARTRIDGE RETAINING NUT TOO LOOSE

NO WATER COMES 

OUT OF FAUCET 

SPOUT. ALL SUPPLIES 

ARE ON.

AERATOR IS CLOGGED.

AERATOR HAS DEBRIS

REMOVE AERATOR.

REMOVE DEBRIS AND

REINSTALL AERATOR

WATER DEFLECTS AT 

AN ANGLE FROM THE 

FAUCET SPOUT

REMOVE AERATOR.

REMOVE DEBRIS AND

REINSTALL AERATOR

Содержание Aquaspec Z82300-XL Series

Страница 1: ... 8 1 REMOVE COLORED HOT COLD INDEX ITEM 1C FROM HANDLE BY PRESSING OUT FROM UNDERSIDE OF HANDLE 1A 8 2 LOOSEN SETS CREW 1B USING 1 8 ALLEN WRENCH 8 3 SLIDE HANDLE ONTO STEM OF CERAMIC MIXING CARTRIDGE 4 8 4 TIGHTEN SETS CREW 1B USING 1 8 ALLEN WRENCH DO NOT OVER TIGHTEN 8 5 PRESS COLORED HOT COLD INDEX 1C INTO HANDLE IT MAY BE NECESSARY TO LUBRICATE THE O RING ON THE HOT COLD INDEX TO FACILITATE A...

Страница 2: ... HANDLE 1A 2 2 LOOSEN SET SCREW 1B IN HANDLE USING 1 8 ALLEN WRENCH 2 3 REMOVE HANDLE FROM CARTRIDGE STEM 2 4 LOOSEN AND REMOVE DOMED CARTRIDGE FLANGE 2 USING FLANGE WRENCH 12E PROVIDED 2 5 LOOSEN AND REMOVE CARTRIDGE RETAINING NUT 3 2 6 PULL CERAMIC MIXING CARTRIDGE 4 BY PULLING ON STEM WHILE WIGGLING FROM SIDE TO SIDE 2 7 INSTALL NEW CARTRIDGE USING THE ALIGNMENT PINS FOR PROPER ORIENTATION AND ...

Страница 3: ... CONTROL G65302 CERAMIC MIXING CARTRIDGE 63233001 8 COVER PLATE G65505 HOSE SPRAY AND HOLDER G67903 Trouble Shooting Guide Problem Cause Solution FAUCET LEAKS FROM UNDER FAUCET HANDLE ALL SUPPLIES ARE ON REMOVE FAUCET HANDLE TIGHTEN CARTRIDGE RETAINING NUT DO NOT OVER TIGHTEN TIGHTEN UNTIL NUT IS SNUG CARTRIDGE RETAINING NUT TOO LOOSE NO WATER COMES OUT OF FAUCET SPOUT ALL SUPPLIES ARE ON AERATOR ...

Страница 4: ...1 Ceramic Mixing Cartridge 1 5 63207001 Internal Body 1 6 63243001 Diverter 1 7 63236222 Quad O Ring 2 8 G63505 13 16 27 Male Aerator 1 9 63209002 10 Swing Spout Body 1 10 63238002 1 4 20 Mounting Stud 1 11 93318012 12 305mm S S Braided Hoses 2 12 G65302 Mounting Components 1 12A 63253002 Gasket 1 Item Part Number Description Qty 12B 63240001 1 4 20 UNC Mounting Nut 1 12C 63239001 Mounting Ring 1 ...

Отзывы: