3544 NASHUA DRIVE, MISSISSAUGA, ONTARIO L4V 1L2  PHONE: 905/405-8272  FAX: 905/405-1292

Item Part No.

Description

1A

P6000-A-AA-CP

1

1

/

2

" x 9" Vacuum Breaker Assembly CP 

(Model ZEMS-6000)

P6000-2-A-AA-CP

1

1

/

2

" x 21" Vacuum Breaker Assembly CP 

(Model ZEMS-6000-2)

P6000-3-A-AA-CP

1

1

/

2

" x 24" Vacuum Breaker Assembly CP 

(Model ZEMS-6000-3)

1B

P6000-1-A-AA-RB

1

1

/

2

" x 11

1

/

2

" Vacuum Breaker Assembly RB 

(Model ZEMS-6140 and ZEMS-6152)

1C

P6000-A-AA-RB

1

1

/

2

" x 6" Vacuum Breaker Assembly RB 

(Model ZEMS-6142)

2

P6000-H

1

1

/

2

" Spud Coupling Assembly CP

3

P6000-HN-RB

1

1

/

2

" Slip Joint Coupling (set of two)

4

P6000-QE3-RB

1

1

/

2

" Double Slip Elbow RB

4A

P6000-QE3-CP

1

1

/

2

" Double Slip Elbow CP

5

P6000-QE1-(“L”)-CP

1

1

/

2

" Outlet Tube CP (specify ‘L’ dim.)

5A

P6000-QT1-4-CP

1

1

/

2

" x 4" Outlet Tube CP

6

P6000-G-TUBE

Flange

7

P6000-HN-CP

1

1

/

2

" Slip Joint Coupling CP

8

P6000-QT4

1

1

/

2

" Coupling S-30 Gasket

9

P6000-QT3-(“L”)-RB

1

1

/

2

" Outlet Tube RB (specify ‘L’ dim.)

10

Specify Series

Valve Body CP (specify valve type)

Item Part No.

Description

11

PESS6000-22

Sensor Cover Plate

12

PESS6000-23

Bracket

13

PESS6000-24

Push Button

14

PESS6000-25

Yoke

15

PEMS6000-26

Sensor

16

PESS6000-27

Bracket Screws (set of two)

17

PESS6000-28

Yoke Screws (set of two)

18

PESS6000-29

Battery Back-Up (optional)

19

PESS6000-30

Wall Bracket (optional)

20

PESS6000-31

Indicator Light Cover Plate (optional)

21

PESS6000-32

Indicator Light (optional)

22

PH6000-HY35

Screws (two required) (optional)

23

P6000-PC6

Power Converter

24

P6000-MJ

Mini Junction Box (optional)

25

PEMS6000-HYM

ZEMS Actuator

26

PH6000-HY35

Screws (four required)

27

PH6000-HY35

Screws (two required)

28

P6000-M10

Washer (supplied with Item 25)

ZEMS-6000
ZEMS-6000-2
ZEMS-6000-3

ZEMS-6140

ZEMS-6142

ZEMS-6152

(SHOWN WITH COVER

REMOVED)

(SUPPLIED WITH

ACTUATOR)

INSTALL WITH FLANGE

AGAINST SPUD

1A

2

3

4

1B

1C

1B

3

5

6 2

3

4

3

5

6

7

4A

3

4

5A

2

3

9

8

18

19

20

21

22

12

16

26

11

23

27

15

14

17

13

10

28

25

24

Содержание AquaSense ZEMS6142AV

Страница 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Страница 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Страница 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Страница 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Страница 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Страница 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Страница 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Страница 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...

Отзывы: