FV38-WCS • Page 5

Figure 9  (Exposed Systems)

Figure 10

Figure 11A  (Without Battery Backup)

Figure 11B  (With Battery Backup)

FLUSH VALVE CL

ø 1-3/4 HOLE
THROUGH
WALL

*3 ± 1/8

1-3/8 REF

*THE 3" DIMENSION

SHOULD BE INCREASED
TO 3-1/4 IF FLUSH VALVE 
DISTANCE TO WALL IS 
LESS THAN 2-1/4".

NOTE: DRAWING DEPICTS A 
TYPICAL INSTALLATION WITH
WATER SUPPLY ON RIGHT 
HAND SIDE OF FLUSH VALVE.

TOP OF

FIXTURE

A

MODEL

A-DIM.

ZEMS-6000

10-1/8

ZEMS-6000-2

22-5/8

ZEMS-6000-3

25-5/8

POWER DISTRIBUTION

OPTIONAL MINI
JUNCTION BOX

MAXIMUM OF
8 ACTUATORS
ALLOWABLE

FINISHED WALL

SENSOR AND
4 x 4 BOX

ACTUATOR

FIXTURE

BOX CLAMP

CABLE

ARMOR

POWER
CONVERTER

110 VAC
RECEPTACLE

TYPICAL INSTALLATION

(ZEMS-6000 SHOWN)

(+) BLACK/WHITE STRIPE

(–) BLACK

PLUG-IN POWER
CONVERTER
120 VAC IN
6 VDC OUT

SENSOR

SENSOR

SENSOR

ACTUATOR

ACTUATOR

ACTUATOR

MANUAL OVERRIDE
PUSHBUTTONS

BRN
GRN
BLU

BRN
GRN
BLU

BRN
GRN
BLU

BRN
GRN
BLU

BRN
GRN
BLU

BRN
GRN
BLU

PB

PB

PB

NOTES:
1.  FAILURE TO OBSERVE PROPER POLARITY WILL RESULT IN FAILURE OF THE SENSOR

AND/OR POWER CONVERTER.

2.  USE #18 AWG FOR INTERCONNECTIONS.

SEE FIGURE 11A FOR 
WIRING OF MULTIPLE ACTUATORS

YELLOW

(+) BLACK/

WHITE 
STRIPE

(–) BLACK

ORANGE

WHITE

BATTERY
BACKUP

LOW

BATTERY

LIGHT

RED

BLACK

PLUG-IN POWER CONVERTER
120 VAC IN
6 VDC OUT

MANUAL OVERRIDE
PUSHBUTTONS

SENSOR

BRN
GRN
BLU

BRN
GRN
BLU

ACTUATOR

PB


STEP 6 – Electrical Hook-up 

(Figures 11A and 11B)

Be certain power is off to prevent damage to electrical components.
Connect the sensor to the actuator and power converter exactly
as shown in Figure 11A, Figure 11B if battery backup is being used.
Also, the wiring diagram on the battery backup may be used.

Double check that power converter polarity is correct.

STEP 7  –  Mount Automatic Sensor 

(Figure 2)

Install the Zurn Automatic Sensor into the 2-gang elec tri cal box
using two (2) long screws provided. Ensure that wires from sensor
case point up. The rubber push caps will be on the left side of
the sensor. The sensor lens faces outward from the finished wall.

STEP 8  –  Mount Yoke and Override Button 

(Figure 5)

Install inner nut, bracket and outer nut on threaded shaft of 
override button. Mount bracket to yoke. Adjust the distance so
that the override button will protrude through the wall plate using
the nuts on each side of bracket. The threaded shaft end of the
override button should be flush with wall plate. Connect the 
override button as per Figure 11A or 11B. Mount the assembled
yoke to the electrical box.

STEP 9  –  Flush Out Supply Line 

(Figure 12)

Make sure the control stop is closed by activating the handle.
Remove valve body cover. Lift out the trip mechanism. Install the
internal plastic cover and valve body cover wrench tight and open
control stop. Turn on water supply to flush line of any debris or
sediment.

After completion, shut off control stop, remove covers and 
reinstall the trip. Install internal plastic cover and valve body
cover, wrench tight.

Содержание AquaSense ZEMS6142AV

Страница 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Страница 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Страница 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Страница 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Страница 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Страница 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Страница 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Страница 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...

Отзывы: