STEP 2  –  Optional Battery Backup and Low Battery
Indicator Light Installation

•  If the battery backup option is being utilized, it is neces sary to

install the battery pack mounting plate and the battery pack
close to the power converter in a convenient location for battery
replacement when needed.

•  Mount the battery pack mounting bracket.

•  Clip the battery pack into location and secure the battery pack

to the bracket with the securing screw.

NOTE: Do not install

the batteries until the Flushometers are

completely installed and operating. The batteries do not have 
to be installed for the system to function.

STEP 3  –  Control Stop Installation 

(Figure 6)

Install the Zurn control stop valve with “Siphon Gard” back check
protection (and wall escutcheon on exposed Flushometer installa -
 tions) to the water supply line with the outlet positioned as required.

NOTE:

For sweat solder applications, see recommended 

instructions included in the Zurn sweat solder kit.

STEP 4  –  Install Vacuum Breaker Flush Connection
Models ZEMS6000, ZEMS6000-2 and ZEMS6000-3 

(Figure 7)

Slide the tube nut, slip washer, rubber gasket and spud escutcheon
over the vacuum breaker tube and insert tube into fixture spud.
Hand tighten spud coupling into fixture spud.

Models ZEMS6140, ZEMS6142 and ZEMS6152 

(Figure 8)

NOTE:

When cutting scoriated pipe, leave a minimum of 1-1/4"

of scoriation to ensure engagement with compression coupling.

Assemble pipe, elbows, couplings, slip washers, rubber gaskets
and flanges as illustrated in Figure 8. Hand tighten all couplings.
Once installation is completed, tighten all connections.

STEP 5  –  Actuator Cable Installation 

(Figures 9 and 10)

1. Drill 1-3/4" diameter hole per Figure 9.

2. Run “fish tape” from electrical box to 1-3/4" hole.

3. Install actuator escutcheon to the actuator pipe with set screw

toward actuator. Do not tighten setscrew at this time.

4. Pull actuator cable through hole with fish tape and back to

electrical box. Secure armored cable to box with box clamp.

5. With escutcheon loose and handle port washer installed, push

cable into wall. The actuator must be angled away from the
valve body at this time until the actuator push rod clears the
handle port flange. The actuator can now be mounted to the
flush valve and tightened.

6. Push escutcheon back to wall and tighten setscrew.

7. The actuator back cover has vent holes top and bottom. After

assembly, the top hole should be sealed with a small dab of
clear silicone sealant.

NOTE:

See Figure 10 for typical installation including optional
mini junction box.

Figure 5

Figure 6

Figure 7

Figure 8

ZEMS6140

ZEMS6142

ZEMS6152

INSTALL 
WITH
FLANGE
AGAINST
SPUD

SUPPLY FLANGE

IRON PIPE NIPPLE

“SIPHON GARD”
CONTROL STOP

STOP CAP
SCREW
COVER

VACUUM BREAKER TUBE

SPUD COUPLING

SLIP GASKET

RUBBER GASKET

SPUD FLANGE

ELECTRICAL BOX

YOKE

OVERRIDE BUTTON

INNER NUT

BRACKET

OUTER NUT

WALL PLATE

Содержание AquaSense ZEMS6142AV

Страница 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Страница 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Страница 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Страница 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Страница 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Страница 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Страница 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Страница 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...

Отзывы: