ZURN AquaSense ZEMS6142AV Скачать руководство пользователя страница 1

FV38-WCS • Page 1

AquaSense

®

AV

Closet ZEMS Series

Automatic Systems Sensor-Operated
AquaVantage Flushometer

Installation, Operation, 
Maintenance, and Parts Manual

Patented and Patents Pending

Sensor-Operated Exposed Systems
ZEMS6000AV
ZEMS6000AV-2
ZEMS6000AV-3

Sensor-Operated Concealed Systems
ZEMS6140AV
ZEMS6142AV
ZEMS6152AV

ZEMS6000AV

ZEMS6142AV

ADA

ADA

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of purchase.
Decorative finishes warranted for one year. We will replace at no cost goods that prove defective provided we are notified in writing of such defect and
the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in accor dance with instruc tions.
We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or conse quen tial damages. The sole and
exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the purchaser shall determine the suitability of
the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith. Where permitted by law, the implied
warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is
limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and lists are
approximate and are not guaranteed.

Содержание AquaSense ZEMS6142AV

Страница 1: ... prepaid at Sanford NC with evidence that they have been properly maintained and used in accordance with instructions We shall not be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determin...

Страница 2: ...nections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces The Zurn AquaVantage is designed to operate over the entire pressure range recommended by plumbing fixture manufacturers and will produce a metered flush when activated Protect the chrome or special finish of this AquaVantage Do not use toothed tools to install or service the valv...

Страница 3: ...upply power to a maximum of eight flush valves for an approximate three day period during a power failure The Low Battery indicator will come on when the batteries have reached a caution level The Flushometers will function when the light is illuminated until the batteries are completely discharged The Low Battery light will illuminate even if the main power has not failed but the batteries have d...

Страница 4: ...leave a minimum of 1 1 4 of scoriation to ensure engagement with compression coupling Assemble pipe elbows couplings slip washers rubber gaskets and flanges as illustrated in Figure 8 Hand tighten all couplings Once installation is completed tighten all connections STEP 5 Actuator Cable Installation Figures 9 and 10 1 Drill 1 3 4 diameter hole per Figure 9 2 Run fish tape from electrical box to 1 ...

Страница 5: ...p Figures 11A and 11B Be certain power is off to prevent damage to electrical components Connect the sensor to the actuator and power converter exactly as shown in Figure 11A Figure 11B if battery backup is being used Also the wiring diagram on the battery backup may be used Double check that power converter polarity is correct STEP 7 Mount Automatic Sensor Figure 2 Install the Zurn Automatic Sens...

Страница 6: ...c Sensor at the desired distance the red light will illuminate when you are within range Repeat adjustment procedure until the desired range is obtained Switch Settings Figure 13 The three switches control the following options They can be activated or deactivated by means of the switches down is on up is off Switch 1 Automatic Flush The unit will automatically flush 24 hours after last user Switc...

Страница 7: ...ration lights red and green The red light is lit when an object is detected The green is lit when the unit is flushing The indicator lights can be manually activated deactivated at any time Maintenance Override For Maintenance Purposes The sensor may be disabled for 10 minutes by placing a magnet on the sensor lens for 3 to 5 seconds After 10 minutes the sensor will automatically resume functionin...

Страница 8: ...m 5A P6000 QT1 4 CP 11 2 x 4 Outlet Tube CP 6 P6000 G TUBE Flange 7 P6000 HN CP 11 2 Slip Joint Coupling CP 8 P6000 QT4 11 2 Coupling S 30 Gasket 9 P6000 QT3 L RB 11 2 Outlet Tube RB specify L dim 10 Specify Series Valve Body CP specify valve type Item Part No Description 11 PESS6000 22 Sensor Cover Plate 12 PESS6000 23 Bracket 13 PESS6000 24 Push Button 14 PESS6000 25 Yoke 15 PEMS6000 26 Sensor 1...