10.) The ZEG urinal valve comes preset for both flow volume

and sensing distance.   Each valve is operated at the fac-
tory using water to insure proper function before being
packed for shipment.   The valve does not require water
pressure regulation for variation in water pressure within
the specified pressure range (20 psi to 80 psi) due to
internal pressure regulation.
Open the stop valve to wide open position using the ad-
justing screw (S) on the front of the stop valve.  The water
volume will never have to be adjusted with the stop valve
as on some conventional urinal installations.
Install vandal resistant stop cover to complete the installa-
tion.

APPENDIX A

TO CHANGE ACTIVATION DISTANCE FOR
THE OBJECT LOCK SENSOR

The valve does not have to be disabled in any way to change
the detection range.  Included with each valve is a Zurn “Magic
Magnet” that is used to intiate the auto-calibration mode.
Calibration is accomplished as follows.

1. Place the Zurn “Magic Magnet” (N) on the left hand side of
the flat top surface of the valve and move around until the LED
comes on.
2. The LED will blink 10 times to indicate magnet is in the
proper position.  Hold magnet in place until 10 flashing lights
occur and the red light turns solid.  The solid red light indi-
cates the electronics are in calibration mode.
3. Remove the magnet and stand in front of sensor about 24”
away for the rest of the calibration.  The calibration process
takes about 60 seconds.  Do not move during this process.
4. When calibration is completed the solid red light will dis-
appear and the LED will blink twice brightly.

Figure 11

11.)   FILTER
     When accessing filter, be certain the stop valve is closed

at adjusting screw (S) Figure 10.

     Activate valve to relieve internal water pressure and to en-

sure stop valve is closed properly.  The filter is accessible
from the bottom of the valve using a slot head screw driver.
The filter will come out with the plug and can be cleaned
with water and a soft brush.
When replacing be sure o-ring (M) is in place and undam-
aged.

M

Filter
Plug

S

N

Figure A

Figure 10

Содержание AquaSense EV ZEG Series

Страница 1: ...be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchasershalldeterminethesuitabilityoftheproductforhisintendeduseandthepurchaserassumesallriskandliability whateverinconnectiontherewith Where permitted b...

Страница 2: ...uld be used on male NPT threads only Figure 2 A Before the supply water is turned on be sure all stop valves are closed off tight The stop valves can be opened and closed by using the adjusting screw S located at the center of the stop valve cap T Stop valve adjustments can only be made by using the adjusting screw S It is not necessary to remove the stop valve cap T when making adjustments If for...

Страница 3: ...s installed open each stop fully for a brief time and catch the water in a two gallon or larger bucket Figure 3 For multiple installations start with the stop valve closest to the water supply and work toward the most remote valve B Due to the small passages and orifices it is not possible to flush the piping through the low volume valve C Once the lines are flushed the valve can be installed A 4 ...

Страница 4: ...ll activate This six second sensing cycle will prevent the valve from flushing needlessly when someone walks by If special circumstances require adjustment of the sensing distance see Appendix A Changing Activation Distance L D H G 9 Wiring installation see fig 8 A Remove the two cover retaining screw and lift the flushometer top cover B Run fish tape through the valve cover tube and wall to the p...

Страница 5: ...as follows 1 Place the Zurn Magic Magnet N on the left hand side of the flat top surface of the valve and move around until the LED comes on 2 The LED will blink 10 times to indicate magnet is in the proper position Hold magnet in place until 10 flashing lights occur and the red light turns solid The solid red light indi cates the electronics are in calibration mode 3 Remove the magnet and stand i...

Страница 6: ...or water Close stop remove and inspect filter Check stop screw Check solenoid leads and and insertion of solenoid plug Visual inspection Check for leak location Check for cuts Solution Reduce sensing range Eliminate reflective object Replace if obstructed or damaged Reinsert plug or repair leads Replace Reset sensor range AppendixA Find source valve and turn on Clean and reinstall filter Open stop...

Страница 7: ...ng Screw 31 Guide Holder 32 Piston Guide 33 Guide O Ring 34 Piston 35 Piston Seal 36 Stop Body 37 Sweat Solder Adapter 38 Supply Cover Tube 39 Setscrew for Cast Wall Escutcheon 40 Cast Wall Escutcheon 41 Hex Wrench 42 Cover O ring Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 3 4 PEG6003 D SD Includes Items 30 35 3 4 Control Stop Replacement Includes PEG6003 C SD Items 2...

Отзывы: