background image

AquaSense

®

  EV

TM

ZEG Series

Automatic Sensor-Operated,

Hard-Wired Flushometer

Installation, Operation, Maintenance,

and Parts Manual

Patented and Patents Pending

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the date of
purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are notified in writing of
such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly maintained and used in
accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages whatsoever, including incidental or
consequential damages. The sole and exclusive remedy shall be limited to the replacement of the defective goods. Before installation and use, the
purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith.
Where permitted by law, the implied warranty of merchantability is expressly excluded. If the products sold hereunder are “consumer products,” the
implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective goods. All weights
stated in our catalogs and lists are approximate and are not guaranteed.

ZEG6003EV-HW6 Flushometer
for Z5798-206-00 Low Flow
Urinal

Sensor-Operated, Hard-Wired Urinal
System

Содержание AquaSense EV ZEG Series

Страница 1: ...be responsible for any labor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchasershalldeterminethesuitabilityoftheproductforhisintendeduseandthepurchaserassumesallriskandliability whateverinconnectiontherewith Where permitted b...

Страница 2: ...uld be used on male NPT threads only Figure 2 A Before the supply water is turned on be sure all stop valves are closed off tight The stop valves can be opened and closed by using the adjusting screw S located at the center of the stop valve cap T Stop valve adjustments can only be made by using the adjusting screw S It is not necessary to remove the stop valve cap T when making adjustments If for...

Страница 3: ...s installed open each stop fully for a brief time and catch the water in a two gallon or larger bucket Figure 3 For multiple installations start with the stop valve closest to the water supply and work toward the most remote valve B Due to the small passages and orifices it is not possible to flush the piping through the low volume valve C Once the lines are flushed the valve can be installed A 4 ...

Страница 4: ...ll activate This six second sensing cycle will prevent the valve from flushing needlessly when someone walks by If special circumstances require adjustment of the sensing distance see Appendix A Changing Activation Distance L D H G 9 Wiring installation see fig 8 A Remove the two cover retaining screw and lift the flushometer top cover B Run fish tape through the valve cover tube and wall to the p...

Страница 5: ...as follows 1 Place the Zurn Magic Magnet N on the left hand side of the flat top surface of the valve and move around until the LED comes on 2 The LED will blink 10 times to indicate magnet is in the proper position Hold magnet in place until 10 flashing lights occur and the red light turns solid The solid red light indi cates the electronics are in calibration mode 3 Remove the magnet and stand i...

Страница 6: ...or water Close stop remove and inspect filter Check stop screw Check solenoid leads and and insertion of solenoid plug Visual inspection Check for leak location Check for cuts Solution Reduce sensing range Eliminate reflective object Replace if obstructed or damaged Reinsert plug or repair leads Replace Reset sensor range AppendixA Find source valve and turn on Clean and reinstall filter Open stop...

Страница 7: ...ng Screw 31 Guide Holder 32 Piston Guide 33 Guide O Ring 34 Piston 35 Piston Seal 36 Stop Body 37 Sweat Solder Adapter 38 Supply Cover Tube 39 Setscrew for Cast Wall Escutcheon 40 Cast Wall Escutcheon 41 Hex Wrench 42 Cover O ring Control Stop Repair Kit and Parts Product No Control Stop Repair Kit for 3 4 PEG6003 D SD Includes Items 30 35 3 4 Control Stop Replacement Includes PEG6003 C SD Items 2...