ZURN AquaSense AV ZER Series Скачать руководство пользователя страница 3

FV237 Rev. E   11/9/11

Page 3

6

7.) 

VISUAL INDICATOR GUIDE

USER-IN-VIEW L.E.D. 

Yellow light flashes 3 times – after

5-second delay – when a user is in view. The yellow light
flashes constantly when a user is in view during the 10-minute
start-up sequence.

OBJECT LOCK SENSOR

BATTERY L.E.D. 

Red light flashes indicating it is time to

replace batteries with 4 new “C” batteries.

COURTESY MANUAL FLUSH BUTTON 

Allows manual

activation of flush when needed.

STEP A 

Use battery compartment

wrench to remove battery compartment
tray.

STEP B 

Pull cover off by rotating battery

side forward and out.

STEP C 

Sensor Adjustor Tool comes in

a built-in storage pocket. Replace after use.

8.) 

ADJUSTING YOUR E-Z FLUSH

6.) 

ACTIVATION

Using supplied battery compartment wrench,
remove battery compartment from the E-Z
Flush™ unit.

Load batteries into compartment tray (note
position of batteries in tray), and reinstall
battery tray into the E-Z Flush unit.

Secure tray with battery compartment wrench. The last three
turns of the wrench will activate the E-Z Flush unit.  The E-Z
Flush System is now operational.

Your E-Z Flush unit comes preset from the factory.  If special
circumstances require adjustment of the activation distance,
see Appendix A – Adjusting Your E-Z Flush.

The E-Z Flush unit has a 10-minute start-up sequence in which
the Object Lock Sensor will flash the User-In-View 

yellow L.E.D.

continuously as long as a user is in view.  After the start-up
sequence is completed and when the Object Lock Sensor has
a user in view, the User-In-View 

yellow L.E.D.

 will flash only 3

times after a 5-second delay.  This delay prevents needless
flushes when someone walks by.  Sensor units should not be
located across from each other or in close proximity to highly
reflective surfaces.

Содержание AquaSense AV ZER Series

Страница 1: ...abor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchasershalldeterminethesuitabilityoftheproductforhisintendeduseandthepurchaserassumesallriskandliability whateverinconnectiontherewith Where permitted by law the implied warran...

Страница 2: ...hread sealing compounds should be used on male NPT threads only 2 Prior to inserting the flush valve tailpiece B into stop valve be certain that the O ring seal C is located in O ring seal groove at the end of the tailpiece and the locking nut D and locking snap ring E are located as shown Care should be taken not to damage the O ring when inserting the tailpiece into the stop valve If lubrication...

Страница 3: ...om the E Z Flush unit Load batteries into compartment tray note position of batteries in tray and reinstall battery tray into the E Z Flush unit Secure tray with battery compartment wrench The last three turns of the wrench will activate the E Z Flush unit The E Z Flush System is now operational Your E Z Flush unit comes preset from the factory If special circumstances require adjustment of the ac...

Страница 4: ... unit 4 Press sensor range reset button the yellow L E D will flash continuously when it has an object in view for the 10 minute reset period 5 Stand at desired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door s...

Страница 5: ...ed Object Lock Sensor range set too close to E Z Flush batteries are dead or water supply is turned off Dirt or debris preventing dia phragm from functioning properly Batteries are dead SOLUTION Remove item covering sensor or adjust Object Lock Sensor activation distance See Appendix B Adjusting the E Z Flush Yellow L E D light will flash only 3 times acknowledging a user is in view after the 10 m...

Страница 6: ...WS Full Flow Closet Kit 4 5 gal flush P6000 ECA FF Ultra Low Flush Urinal Kit 0 125 gal flush P6000 EUA ULF Extra Water Saver Urinal Kit 0 5 gal flush P6000 EUA EWS Low Consumption Urinal Kit 1 0 gal flush P6000 EUA WS1 Water Saving Urinal Kit 1 5 gal flush P6000 EUA WS Full Flush Urinal Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Clos...

Отзывы: