ZURN AquaSense AV ZER Series Скачать руководство пользователя страница 2

FV237   Rev. E   11/9/11
Page 2

PRIOR TO INSTALLATION

Prior to installing the ZER Flushometer, install the
items listed below:
• Closet or urinal fixture
• Drain line
• Water supply line

IMPORTANT:

• ALL PLUMBING IS TO BE INSTALLED IN ACCORDANCE WITH
APPLICABLE CODES AND REGULATIONS.
• WATER SUPPLY LINES MUST BE SIZED TO PROVIDE AN
ADEQUATE VOLUME OF WATER FOR EACH FIXTURE.
• FLUSH ALL WATER LINES PRIOR TO OPERATION (See Step
9).
• DIRT AND DEBRIS CAN CAUSE FLUSH VALVE TO RUN CON-
TINUOUSLY.

The ZER is designed to operate with 20 to 80 psi (138 to 552 kPa) of water pressure. THE MINIMUM PRESSURE REQUIRED TO
THE VALVE IS DETERMINED BY THE TYPE OF FIXTURE SELECTED. Consult fixture manufacturer for pressure requirements.
Protect the chrome or special finish of this flushometer. DO NOT USE TOOTHED TOOLS TO INSTALL OR SERVICE THE VALVE.

1.) 

Install stop valve assembly 

(A)

 using proper size supply

escutcheon and sweat solder adapter kit if applicable.  Thread
sealing compounds should be used on male NPT threads only.

2.) 

Prior to inserting the flush valve tailpiece 

(B)

 into stop valve,

be certain that the O-ring seal 

(C)

 is located in O-ring seal groove

at the end of the tailpiece and the locking nut 

(D) 

and locking

snap ring 

(E)

 are located as shown.  Care should be taken not

to damage the O-ring when inserting the tailpiece into the stop
valve. If lubrication is needed, wetting the O-ring with water will
be sufficient.

3.) 

Insert the flush valve tailpiece 

(B)

 into the stop valve 

(A)

 and

hand tighten the lock nut 

(D)

 to the stop valve. Plumb the entire

unit.

4.) 

Determine the length of vacuum breaker tube 

(F)

 required

to join the flush valve and fixture spud.  Cut the vacuum breaker
tube, if required, to this length.  Assemble the vacuum breaker
tube assembly and spud nut assembly to the flush valve and
fixture spud.

5.) 

Hand tighten spud nut and vacuum breaker tube nut to fix-

ture and flush valve.  Adjust the valve assembly for plumb.
Tighten fixture spud nut, vacuum breaker tube nut and lock nut
with a wrench. 

 Do not turn water on until batteries are in-

serted – see 6.

1

3

2

4

E

C

A

D

F

B

B

D

A

Содержание AquaSense AV ZER Series

Страница 1: ...abor charges or any loss injury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchasershalldeterminethesuitabilityoftheproductforhisintendeduseandthepurchaserassumesallriskandliability whateverinconnectiontherewith Where permitted by law the implied warran...

Страница 2: ...hread sealing compounds should be used on male NPT threads only 2 Prior to inserting the flush valve tailpiece B into stop valve be certain that the O ring seal C is located in O ring seal groove at the end of the tailpiece and the locking nut D and locking snap ring E are located as shown Care should be taken not to damage the O ring when inserting the tailpiece into the stop valve If lubrication...

Страница 3: ...om the E Z Flush unit Load batteries into compartment tray note position of batteries in tray and reinstall battery tray into the E Z Flush unit Secure tray with battery compartment wrench The last three turns of the wrench will activate the E Z Flush unit The E Z Flush System is now operational Your E Z Flush unit comes preset from the factory If special circumstances require adjustment of the ac...

Страница 4: ... unit 4 Press sensor range reset button the yellow L E D will flash continuously when it has an object in view for the 10 minute reset period 5 Stand at desired activation distance 6 Use sensor adjustor tool and turn Distance Adjustment Screw all the way down and then turn slowly up until yellow L E D begins to flash 7 Ensure Object Lock Sensor is not detecting stall door or wall by closing door s...

Страница 5: ...ed Object Lock Sensor range set too close to E Z Flush batteries are dead or water supply is turned off Dirt or debris preventing dia phragm from functioning properly Batteries are dead SOLUTION Remove item covering sensor or adjust Object Lock Sensor activation distance See Appendix B Adjusting the E Z Flush Yellow L E D light will flash only 3 times acknowledging a user is in view after the 10 m...

Страница 6: ...WS Full Flow Closet Kit 4 5 gal flush P6000 ECA FF Ultra Low Flush Urinal Kit 0 125 gal flush P6000 EUA ULF Extra Water Saver Urinal Kit 0 5 gal flush P6000 EUA EWS Low Consumption Urinal Kit 1 0 gal flush P6000 EUA WS1 Water Saving Urinal Kit 1 5 gal flush P6000 EUA WS Full Flush Urinal Kit 3 0 gal flush P6000 EUA FF Repair Parts Inside Parts Product No Urinal Relief Valve Item 12 P6000 EU13 Clos...