RECOMMENDATION FOR THE INSTALLATION
4
FUNCTION OF DIP SWITCH
1.Time-lapse alarm switch
Time-lapse alarm
Directly
2.PGM control switch
suggestive sound
No sound
3 Battery connect switch
Battery connect
Battery disconnect
4 LED
Led on
Led off
FUNCTION AND TEST
1.
LED AND LAMP TEST
Pick the DIP switch 1 in ON mood (the others also in ON mood), 12VDC power connected, the siren the
siren sound" DEE DEE DEE", 4 LEDs flash at the same time. The tube is on. After 10 seconds, the siren
start to sound" JU JU JU. 4 LEDs flashes one by one in turn. The tube in on and the power indicating LED
twinkles. After 10 seconds, there will be fire alarm sound, LED flashes quickly and the tube also flashes.
We call it time-pulse alarm.
Pick the the DIP switch 1 in OFF mood (the others in ON mood), the first sound of the siren will be " JU
JU JU" directly.
2.
TRIGGERING TEST
Pick the DIP switch 3 in the OFF mood (the others in ON mood), if there is no any triggering feeding,
the siren is static (LED lights) and waiting for feeding to alarm, when positive triggering feeding supplied,
the siren start (time-lapse )alarm.
3.
ENABLE AND DISABLE TIME-LAPSE FUNCTION
Pick the DIP switch 1 in the ON mood, the time-lapse function enable, or disable
4.
PROMPT SOUND SETTING
Pick DIP switch 2 in the ON mood, once the siren doesn't be connected the alarm panel properly, it will give a
soft prompt sound, to suggest you to check the connection again.
5.
POWER FAILURE ALARM
After the siren is connected correctly, if the DIP switch 2 is in ON mood, in any case the out power failure, the
siren would alarm. If it is in OFF mood, it will alarm only when it is triggered.
6.
AUTOMATICALLY CHARGE THE BACKUP BATTERY
If the Green LED light, it indicates the voltage of the battery is low
(<8V
),and the siren is charging the battery
automatically.
NOTES
The standard alarm panel 728(Paradox),if you use different alarm panel, pls consult your manual of the alarm
panel.