ZUDSEC ZDSH-108 Скачать руководство пользователя страница 4

RECOMMENDATION FOR THE INSTALLATION 

 

 

 

  4 

 

 

 

FUNCTION OF DIP SWITCH                                                                                                                                   

 

1.Time-lapse alarm switch 

Time-lapse alarm 

Directly 

 

2.PGM control switch 

suggestive sound 

No sound 

3 Battery connect switch 

Battery connect 

Battery disconnect 

4 LED 

Led on 

Led off 

 

FUNCTION AND TEST                                                                                                                                                       

 

1.

 

LED AND LAMP TEST   

Pick the DIP switch 1 in ON mood (the others also in ON mood), 12VDC power connected, the siren the 

siren sound" DEE DEE DEE", 4 LEDs flash at the same time. The tube is on. After 10 seconds, the siren 

start to sound" JU JU JU. 4 LEDs flashes one by one in turn. The tube in on and the power indicating LED 

twinkles. After 10 seconds, there will be fire alarm sound, LED flashes quickly and the tube also flashes. 

We call it time-pulse alarm.   

Pick the the DIP switch 1 in OFF mood (the others in ON mood), the first sound of the siren will be " JU 

JU JU" directly. 

2.

 

TRIGGERING TEST 

Pick the DIP switch 3 in the OFF mood (the others in ON mood), if there is no any triggering feeding,   

the  siren  is  static  (LED  lights)  and  waiting  for  feeding  to  alarm,  when  positive  triggering  feeding  supplied,                           

the siren start (time-lapse )alarm.   

3.

 

ENABLE AND DISABLE TIME-LAPSE FUNCTION 

Pick the DIP switch 1 in the ON mood, the time-lapse function enable, or disable 

4.

 

PROMPT SOUND SETTING 

Pick DIP switch 2 in the ON mood, once the siren doesn't be connected the alarm panel properly, it will give a 

soft prompt sound, to suggest you to check the connection again. 

5.

 

POWER FAILURE ALARM 

After the siren is connected correctly, if the DIP switch 2 is in ON mood, in any case the out power failure, the 

siren would alarm. If it is in OFF mood, it will alarm only when it is triggered. 

6.

 

AUTOMATICALLY CHARGE THE BACKUP BATTERY 

If the Green LED light, it indicates the voltage of the battery is low

(<8V

),and the siren is charging the battery 

automatically. 

 

 

 

 

 

 

 

NOTES                                                                                                                                                                                   

The standard alarm panel 728(Paradox),if you use different alarm panel, pls consult your manual of the alarm 

panel.                                           

Отзывы: