RECOMMENDATION FOR THE INSTALLATION
2
Picture 2:
Siren connect with the battery, the “+”
connect with “BAT”, “ - ” connect with the
terminal block 12v “ -” , TRIG connect with
the positive output power supply of the
host ,the terminal block 12v “ - ” also
should connect with the “ -” of the battery
back up of the host , the 12v “+” of the
siren connect with the “+” side of the
battery back up of the host , the power
supply of the host need to connect with the
host , then it will be trigger the siren
working.
Picture 3:
If the host has the program function, the
terminal block PGM of the siren connect
with the terminal block PGM of the host. The
ending resistance 820 Ohm connect with the
terminal block PGM and BAT of the alarm .
The other connect way is the same like the
picture 2
Picture 4:
If the host is without the program function,
the terminal block PGM of the siren connect
with the terminal block BAT . The other
connect way is the same like the picture 2.