RECOMMENDATION FOR THE INSTALLATION 

 

 

 

  3 

 

 

 

 

Picture 5: 
 
The  connect  ways  is  the  same  like  the 
picture  2  .  The  siren  will  be  triggered 
when the output power is cut off.   

 

 

 

 

 

 

 

 

 

TERMINAL OF CONNECTION                                                                                                                                                     

 

TERMINALS 12VDC+&-: 

they are the power terminals. 

TREMINAL TRIG:

 it’s the positive triggering terminal 

 

TERMINAL  PGM:

  It’s  a  optional  terminal,  if  the  alarm  panel  has  PGM  function,  the  PGM 

terminal  in  the  alarm  panel  should  connect  to  this  terminal.  The  resistance  820  Ohm  should 

connect the PGM terminal and BAT terminal.. If the alarm panel do not have PGM function, the 

PNG terminal should connect the BAT terminal. 

TERMINAL BATTERY:

 Connecting with the positive input of the backup battery. 

TERMINAL  TEMP: 

These two terminal should connect with the  Micro switch

 (

anti-removing) 