Commands to the extraction system:
The various extraction power levels can
be switched, for example, in relation to
the dust level (roughing or polishing).
Filter cleaning can take place in addition
to the automatic mechanism of the
extraction system during the operating
pauses of the machine.
Input 1
Input 2
Function
0V
0V
Extraction OFF
24V
0V
Extraction ON with power level 1
0V
24V
Carry out filter cleaning
24V
24V
Extraction ON with power level 2
Output 1
Output 2
Status
0V
0V
Extraction not ready / OFF
24V
0V
Filter cleaning running
0V
24V
Filter replacement necessary
24V
24V
Extraction ready / Standby