Safety Instructions
Warning: Your safety is very important to us .To ensure to use the product correctly and safely, we would like to draw your attention to read the warning and
entire User Manual before using the product. These are important safety information and should be observed at all times.
1. Please handle the devices lightly, Do not subject the product to impact or shock.
2. Do not immerse the product in water. Water can cause electric shock, fire or malfunction which may result in damage.
3. Do not keep the product under the hot and moisture environment. Keep the product away form the heat source or near water.
4. Please use only the included power adaptor. Improper power adaptor or power sources can cause serious damage to the product, or result in injury or death
to the user.
Caring for product
To ensure you receive the maximum benefit from using this product, please observe the follow guidelines.
1. Cleaning— Disconnect the power before clean. Use a damp cloth, do not use the liquid cleaning agent, such as benzene, thinner or aerosols.
2. Repair----Do not attempt to repair the product or modify the circuitry by yourself. Please contact with the local dealer or a qualified repairman if the product
needs servicing.
3. Air circulation---The vents allow the air circulation liquid for measurement of the CO2 concentration and the ventilation should not be blocked.
Customize Settings
When the power has been connected, The ZG1163 CO2 monitor will begin to work. In order to meet your personal requirements, it is advisable to set up the
customizing parameters.
WarmUp: It lasts approximately 1min before WARM UP disappears; all MODE functions will not response during warm up.
Temperature (ºC/ºF) and Ventilation Rate:
1. Press up/down to select the temperature and ventilation rate modes.
2. When pressing up button, the LCD display sequence is Temp ºC -> Temp ºF -> Vent Rate lps -> Vent Rate cfm/p
When pressing down button, The LCD display sequence is reverse.
*Note: Temp ºC refers to Temperature in Celsius; Temp ºF refers to Temperature in Fahrenheit.
Vent Rate lps refers to Liter Per Second Per Person; Vent Rate cfm/p refers to Cubic Feet Per Minute Per Person
Using the Alarm function:
1. Press Mode, the speaker icon flashes simultaneously.
2. Press Enter, use up/down to select the on/off.
3. Press Enter again to save the data.
Note: The factory setting with alarm is buzzer off, user can set the alarm on/off according to alarm function instruction.
Using the ALTI mode:
1. Press Mode,the ALTI icon flashes.
2. Press Enter, ALTI shows on the display, press the mode button to alter between the m( meter) and ft(feet).
3. Adjust altitude (step=100m/500ft) by up/down button.
4. Press Enter again to save the data.
Using the ALARM Level mode:
1. Press Mode, the ALARM icon flashes.
2. Press Enter. Using the Up/Down to set the parameter.
3. Press Enter again to save the data.
*Note:1
)
When CO2 Alarm level is
≧
1,000 ppm, the interval is ±100ppm, when the CO2 Alarm level is
<
1,000 ppm, the interval is ±50 ppm
2) After setting with new alarm level parameter, the green LED will light when CO2 concentration below this alarm level. The red LED will light when CO2
concentration exceeds the second level (the new alarm level plus 400ppm), the yellow LED will light when CO2 concentration is between alarm level and second
level. For example, if the new alarm level is 800ppm, so the second level is 1200ppm.The green LED will light when CO2 concentration below 800ppm, the red
LED will light when CO2 concentration exceeds 1200ppm, the yellow LED will light when CO2 concentration is between 800ppm and 1200ppm