Hardware Development Guide of Module Product
17
All Rights reserved, No Spreading abroad without Permission of ZTEWelink
Mode
Status
Average
Remark
LTE
With no service
TBD
IDLE mode
With data transmission
TBD
LTE mode
Note: The above average current is acquired under the maximum transmission power. Under different environments, the testing
results might be slightly different. Take the actual situation as the reference.
5.2
Power-on/Power-off Flow
ZM8620 wirelesses MINI PCIE MODULE can be POWER-ON or POWER-OFF by the
POWER_ON signal.
The POWER_ON is low in the beginning. Once there gives POWER_ON a high RISE EDGE
more than 1.2V, the ZM8620 MODULE will be Power-on. That is the Power-on flow.
If there gives POWER_ON a low LEVEL, the POWER_ON signal becomes low; the ZM8620
MODULE will be Power-off. That is the Power-off flow.
5.3
Resetting Flow
The failing edge of POWER_ON reset signal initiates a reset process. The module is reset by
driving this pin with a low pulse.
Increasing
resetting
1
0
PERST#
signal
100ms
Figure 5-1 Module Reset Flow
6 RF Specifications
The following content is the description of module ZM8620 radio frequency performance.