ZXSDR R8882 L268 User Manual
3.
Connect end A of the fiber to baseband-RF fiber interface (OPT1/2) of ZXSDR R8882
L268. Connect end B of the fiber to baseband-RF interface (OPT1/2) of the other
ZXSDR R8882 L268.
4.
Screw down the outdoor seal component for waterproof.
– End of Steps –
4.6.7 Installing Environment Monitor Cable
Prerequisite
The ZXSDR R8882 L268 cabinet has been installed and securely fastened.
Context
The environment monitor cable provides a 485 interface, used for ZXSDR R8882 L268
environment monitor. It also provides four extension accesses for external dry contact
monitor.
End A is circular 8-core plug and end B is made depending on actual conditions. The total
length is 3m.
shows the structure of environment monitor cable.
Figure 4-41 Environment Monitor Cable
The connector, connecting the environment monitoring cable to ZXSDR R8882 L268, is
8-core straight welded connector (pin) mounted on panel. The connector appearance is
shown in
.
Figure 4-42 Appearance of Environment Monitor Cable
The cable connector pins and connection are shown in
Table 4-5 Cable Pin Description
Pin
Core color
Signal Description
PIN1
Brown
Dry contact input, positive polarity
4-32
SJ-20110104194923-001|2011-01-19(R1.0)
ZTE Proprietary and Confidential