Chapter 3
Error! Style not defined.
Confidential and Proprietary Information of ZTE CORPORATION
37
2. Mount the cabinet on the installation plate, and insert the 4
hex flange bolts at the back of the cabinet through the larger
parts of the cucurbit holes on the plate.
3. Move the inserted 4 hex flange bolts into the smaller parts of
the cucurbit holes to fix the cabinet to the plate.
4. Tighten the 4 hex flange bolts.
Note:
The diameter of the pole should be within the range of 30
mm (1 3/16 in) to 60 mm (2 6/16 in).
E
ND OF
S
TEPS
.
External Cables Installation
The external cable installation includes:
Grounding cable installation
Ethernet cable installation
Power cable installation
GPS RF cable installation
Grounding Cable Installation
The following describes prerequisites and procedure of
grounding cable installation.
The connection point for the indoor grounding copper bus-bar is
available.
Prepare a length-proper grounding cable according to the actual
situation. Use a 16mm
2
(6 AWG) olivine copper cable to make
the grounding cable.
Crimp a bare round metal terminal (also called lug) at both ends
of the cable respectively.
Perform the following steps to install the grounding cable.
1. Connect one bare terminal of the grounding cable to the
protective grounding terminal that is located at the M5 bolt
of the power cable interface on the ZXMBW E9200 cabinet.
2. Connect the other end of the grounding cable to the specified
indoor grounding copper bus-bar.
Note:
To ensure reliable connection, press the lugs of grounding
cable to make the cable in good contact with the other parts.
E
ND OF
S
TEPS
.
Prerequisites
Steps