ZXA10 C300 Configuration Manual (CLI)
Figure 17-3 Networking Diagram of BFD for VCCV
The PW redundancy group works in non-negotiation 1:1 mode.
The primary PW is
revertive when it recovers.
BFD packets that notify PW alarms are encapsulated in VCCV mode (IP/UDP BFD
encapsulation).
Configuration Data
lists the configuration data of the BFD for VCCV.
Table 17-4 Configuration Data of BFD for VCCV
Item
Data
Loopback interface
l
ID: 1
l
IP address: 1.1.1.1/32
L3 interface 1
l
VLAN ID: 10
l
Interface: gei_1/21/1
l
IP address: 30.1.1.1/24
L3 interface 2
l
VLAN ID: 11
l
Interface: gei_1/21/2
l
IP address: 10.1.1.2/24
Reserved VPN VLAN
VLAN ID: 4090
PW class
l
Name: pw1
l
Control word: not preferred
l
Control Channel (CC) type: type2
(out-of-band)
l
Connection Verification (CV) type: lsp-ping
bfd-ipudp-fo
C300-1
17-12
SJ-20130520164529-007|2013-06-30 (R1.0)