ZXMP M600 (V1.0) Technical Manual
4-8
2km
B
A
C
D
Legend:
Node:
E
osc
osc
osc
osc
osc
osc
1311 window
2xGE
2xGE
4x622M
4x622M
1611(8)
1591(7)
1571(6)
1551(5)
1531(4)
1511(3)
1491(2)
1471(1)
15km
18km
20km
5km
8+1 wave
Add/drop
2+1 wave
Add/drop
2+1 wave
Add/drop
2+1 wave
Add/drop
2+1 wave
Add/drop
Integrated access without OTU
Configure OTU
Configure OTUP (with protected OUT; dotted line indicating the protection route)
Optical monitor
One board
Fig. 4.3-2 Service Requirements
4.3.1 Configuration Implementation
4.3.1.1 Configuration Description
According to the service requirements in Fig. 4.3-2, the required boards are analyzed as
follows:
1. NCP board
One NCP board should be configured for each node and be installed in the
master CWU shelf.
As the ZXMP M600 is configured as OADM equipment in the global network
and the monitoring channel is 1310nm, NCP board of which the monitoring
channel type is line and the wavelength is 1310nm should be configured in each
node.
2. PCW board
Two same PCW boards will be configured for each shelf according to the type
of DC power supply equipped in the machine room.