ZXSDR BS8900 Hardware Manual
Storage Battery
Temperature Monitoring
Cable
The storage battery temperature monitoring cable is used to mon-
itor the temperature in the storage battery and report monitoring
results to the baseband subrack.
Figure 49
shows the appearance of the temperature monitoring
cable.
F
IGURE
49
T
EMPERATURE
M
ONITORING
C
ABLE
A
PPEARANCE
Storage Battery Water
Monitoring Cable
The storage battery water monitoring cable is used to monitor
whether the storage battery is watered and transmit electrical sig-
nals of the water sensor to the baseband subrack.
Figure 50
shows the appearance of the storage battery water mon-
itoring cable.
F
IGURE
50 S
TORAGE
B
ATTERY
W
ATER
M
ONITORING
C
ABLE
A
PPEARANCE
End A is a water sensor and put on the bottom of the storage
battery cabinet while end B is connected with the environment
monitoring cable led from the lightning subrack of the baseband
cabinet.
E1/T1 Cable on Lightning
Subrack LPU
The E1/T1 cable on lightning subrack LPU transmits E1/T1 signals
between Abis interfaces or cascaded
BTS
s and is classified into
4–channel E1/T1 cable and 8–channel E1/T1 cable.