ZXSDR BS8900 Hardware Manual
RRU Modules
Fan Subrack
The fan subrack locates in the RF cabinet above the power distri-
bution subrack.
The fan subrack consists of fan control module (FCE), temperature
sensor and 6 fans.
Figure 31
shows the fan subrack structure.
F
IGURE
31 F
AN
S
UBRACK
S
TRUCTURE
1. POWER
2. MON
Power Distribution Subrack
The power distribution subrack locates in the RF cabinet between
the fan subrack and RF subrack.
The power distribution subrack consists of 7 branch power circuit
breakers, 2 bus bar jackets, spacer and the shell with the break-
ers controlling over the power distribution to 6 RSUs and the fan
subrack.
Figure 32
shows the structure of the power distribution subrack.