Values: 5
–
600 (seconds). 30 (seconds) –
default setting.
Size: 2 byte dec.
Trigger Action
Parameter 3: You can choose if your Mini Sensor turns an associated device on or off when
sending the BASIC SET command. Use value 0 to turn the associated device OFF and value
255 to turn it ON. Adjust brightness level for a Z-Wave dimmer (Multilevel switch) by putting in
any value between 1 and 99.
Values: 0 –
OFF; 1 –
99 (% of light); 255 – ON (default).
Size: 1 byte dec.
Light Trigger
Parameter 8: Use this parameter to enable and disable the light sensor as secondary trigger. If
this feature is enabled, the Mini Sensor will activate associated devices based on motion AND
light level set in parameter 5.
Values: 0
–
Light trigger disabled (default). 255 –
Light trigger enabled.
Size: 1 byte dec.
Light Trigger Level
Parameter 5: Set your light sensor as a secondary trigger for associated devices. If light level in
a room falls beyond the set point and motion is detected, the Mini Sensor will send
BASIC_SET command to associated devices to turn ON. The number entered as the value
corresponds to the number of LUX. So if 100 is entered by default, the associated device will
turn ON if light level last reported by the sensor is under 100 LUX and if motion has been
detected by your Mini Sensor.
Values: 0
–
1000 (LUX). 100 (LUX) –
default setting.
Size: 2 byte dec.
Light Polling Interval
Parameter 7: Decide how often you want the Mini Sensor to report light level to the controller
and associated devices. The number entered as the value corresponds to the number of
seconds. So if 180 is entered by default, the Mini Sensor will report light level values every 3
minutes. The value set for this parameter can NOT be greater than the wake-up interval.
Values: 60
–
360000 (seconds). 180 (seconds) –
default setting.
Size: 2 byte dec.
NOTE: Small interval will increase activity and decrease battery life.
Light Report
Parameter 9: Choose light level change to be reported by the Mini Sensor to the controller.
The number entered as the value corresponds to the number of LUX. So if 100 is entered by
default, the sensor will report any change of 100 LUX or more.
Values: 0
–
255 (LUX). 100 (LUX) –
default setting.
Size: 2 byte dec.
LED Notifications
Parameter 10: Use this parameter to turn LED notifications on or off for motion detection.
Values: 0 –
LED disabled; 1 –
LED enabled (default).
Size: 1 byte dec.