background image

ISSUE 01

Page 29

http://www.meyertech.demon.co.uk

MAN-328

MEYERTECH DIVISION

ISSUE 01

Office Block One

Southlink Business Park

Oldham

England

OL4 1DE

Sales Support

(

+44 (161) 628 8406

2

 

+44 (161) 628 9811

Email:  [email protected]

Technical Support

Oldham

(

+44 (161) 628 8406

Email:  [email protected]

http://www.meyertech.demon.co.uk

Содержание ZoneVu 328 Series

Страница 1: ...SERIES 328 VIDEO MATRIX SYSTEM USERS MANUAL ...

Страница 2: ...4 3 SETUP MATRIX 9 4 3 1 CAMERA OPTIONS 9 4 3 2 MONITOR OPTIONS 11 4 3 3 ALARM OPTIONS 11 4 3 3 1 Alarm Reporting 12 4 3 3 2 Contract Alarms 13 4 3 3 3 Alarm Handling 14 4 3 4 SEQUENCING OPTIONS 15 4 3 5 MISCELLANEOUS OPTIONS 16 4 3 5 1 Setup of Video Inputs 16 4 3 5 2 Setup of Contact Inputs 17 4 3 5 3 Number Of Keyboards 17 4 3 5 4 Control Time out 17 4 4 SETUP TIME DATE 18 4 5 DIAGNOSTICS 18 4 ...

Страница 3: ... every effort has been made to confirm the information in this document is correct MEYERTECH DIVISION cannot accept any liability for any errors omissions and or incorrect information contained within this document No part of this document may be reproduced or distributed in any form or by any means without prior written consent from MEYERTECH DIVISION MEYERTECH DIVISION are committed to continuou...

Страница 4: ...he technical help line listed on page 29 Information regarding other MEYERTECH products and technical information can be found on the MEYERTECH World Wide Web site by pointing your Internet browser to http www meyertech demon co uk 2 FEATURES 32 Bridged Camera Inputs per matrix System expandable to 96 Camera Inputs 8 Monitor Outputs Support for up to 8 keyboards Including a socket for direct attac...

Страница 5: ...ZARDOUS VOLTAGES THIS EQUIPMENT MUST BE EARTHED TO PREVENT FIRE OR SHOCK HAZARD DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE Unpack the ZVM 328 and check the contents against the list below ZVM 328 3u 19 Low Profile Case Power Supply 12V 3 1 SYSTEM EXPANSION The ZVM 328 Video Matrix is expandable in blocks of 32 inputs to a maximum size of 96 cameras and 8 monitors Hence the three matrix optio...

Страница 6: ...s typically 2km 5 The maximum cable run for VICTA Twisted Pair is typically 600m for type RG11 cable 6 The maximum number of Telemetry Receivers that can be connected to a driver output is 32 7 Bridging to other equipment is achieved using the additional BNC terminals located next to each video input If an input is bridged the termination link should be removed 8 All unused video inputs must be te...

Страница 7: ...dc and view monitor output 1 Instructions will appear on the display see below 4 To move the bar highlighter down one position insert the link pause momentarily and then remove the link 5 When the bar highlighter is pointing to the correct configuration for the current matrix re fit the link and power the ZVM 328 OFF 6 Repeat for each matrix When each matrix has been configured in the above manner...

Страница 8: ...board please refer to the ZVK 002 user manual Order Code MAN 002 Using the ZVK 007 The following ZVK 002 keys are used to configure the matrix ENT Proceed to the selected option Also used to accept parameters and to toggle through available options DEL Used to navigate through the menus and to delete characters whilst editing text captions For further information regarding the ZVK 007 keyboard ple...

Страница 9: ... The CAMERA OPTIONS MENU allows the user to configure all options on a camera by camera basis MAIN MENU Setup Matrix Setup Time Date Diagnostics Load Defaults Return To Operation SETUP MATRIX MENU Camera Options Monitor Options Alarm Options Sequencing Options Miscellaneous Return To Main Menu CAMERA OPTIONS MENU Camera 1 Video PRESENT Head Type ZoneVu Set Caption Caption ON Time Date BOTH Text Po...

Страница 10: ...amera caption text position TOP BOTtom or OFF This option is applied to both camera and monitor captions as well as time and date text Time Date Toggle time and date display TIME DATE BOTH or OFF Head Type This option defines the RS 422 telemetry protocol output Options available are DomeVu Must be selected when driving Meyertech telemetry receivers DVR xxx ZoneVu Must be selected when driving Mey...

Страница 11: ...between 1 and 8 Set Caption Allows the user to enter a caption for the current monitor of up to 5 characters in length Caption Toggle monitor caption text ON or OFF Camera Text Toggle camera text ON or OFF allows camera text to be turned off by monitor not turned on 4 3 3 ALARM OPTIONS MONITOR OPTIONS MENU Monitor 1 Set Caption Caption ON Camera Text ON Return To Matrix Menu ALARM OPTIONS MENU Ala...

Страница 12: ...ct Alarm ON or OFF Master or Standalone Matrices only Video Loss ON or OFF Must be defined on Standalone Master Slave Matrices Relay Output Action is configurable as Off Latched or Pulsed for 1 second Master or Standalone Matrices only ALARM REPORTING Contact Alarms OFF Video Loss OFF Relay Output LATCH Return To Alarm Menu ...

Страница 13: ...the current alarm of up to 10 characters in length Alarm Status Toggle Alarm Status normal condition between N O Normally Open Contact N C Normally Closed Contact or OFF Ignore Alarm Contact Input Priority Alarm priority 1 9 9 Highest Used when Queue Type selected is PRIOR Priority as opposed to CHRON Chronological Relay Enable or Disable relay action taken when alarm occurs Events Each Alarm trig...

Страница 14: ...ring User control intervention after a camera has been event driven will override the Auto Cancel facility Cancel Time Time between alarm de activating and cameras returning to last position tour Report Monitor The monitor upon which all alarm reporting OSD text is written Queue Length Number of alarms allowed to be queued at any one time Queue Type Determines whether alarms progress to the top of...

Страница 15: ...t for Dwell Time which is a global setting will then be updated with the current operating values Editable Fields are Pattern Enter a pattern number between 1 and 8 Each pattern can hold up to 32 Cameras Position Indicates the current position in the current pattern which is to be edited Range 1 32 Camera Allows the user to enter the camera to be sequenced in the pattern number and position number...

Страница 16: ...ckly setting up the Video field seen in the Camera Options menu See section 4 3 1 Use the MONITOR key to manoeuvre through the menu and the ENTER key to place a marker next to each input where video is present SETUP VIDEO INPUTS 1 x 12 x 23 x 2 x 13 x 24 x ENT 3 x 14 x 25 x Marks 4 x 15 x 26 x 5 x 16 x 27 x 6 x 17 x 28 x DEL 7 x 18 x 29 x key 8 x 19 x 30 x moves 9 x 20 x 31 x 10 x 21 x 32 x 11 x 2...

Страница 17: ...es the number of keyboards polled by the Matrix Generally keyboard MAC numbers must lie within the range 01 and 08 If the Keyboards is set to 4 the matrix will poll four keyboards with the MAC numbers 01 02 03 and 04 4 3 5 4 Control Time out If the Control Time out feature is enabled keyboards are forced to relinquish control after the specified period of time of inactivity This option can be swit...

Страница 18: ...tions for time and date are set on a camera by camera basis within the CAMERA OPTIONS MENU Each field must be set individually and the real time clock will only take on the new values when Initialise clock is selected 4 5 DIAGNOSTICS TIME DATE MENU Set Hours 17 Set Minutes 00 Set Day 06 Set Month 11 Set Year 96 Initialise Clock Return To Main Menu DIAGNOSTICS MENU Test Video Inputs Test Contact Al...

Страница 19: ...is option gives quick diagnostic facilities for testing the matrix s alarm contact inputs The example below shows no alarms Closed Circuit I e All Open 4 5 3 LOAD DEFAULTS 1 ok 12 23 Video 2 ok 13 24 Inputs 3 ok 14 25 Present 4 ok 15 26 5 ok 16 27 6 17 28 ENT 7 18 29 to 8 19 30 Test 9 20 31 10 21 32 11 22 MATRIX ACTIVE CONTACTS 1 0 12 0 23 0 2 0 13 0 24 0 ENT 3 0 14 0 25 0 To 4 0 15 0 26 0 Test 5 ...

Страница 20: ...ble information such as camera captions text options and sequences See section 4 7 for default data The user is given the option to abort loading default data if necessary To re boot the ZVM 328 and load default factory conditions i Remove power from the matrix ii Remove link located next to power connector iii Apply power to the matrix iv Replace Link ...

Страница 21: ...Text ON By Sequence Pattern Position nn Camera nn Pattern Size 32 By Contact Alarm Caption Alarm nn Status N O Relay ENABLE Priority 1 By Alarm Event Camera Nn Monitor 1 Preset 0 Keyboard 1 Cam to Mon ON Cam to Pre ON Report to Kbd ON Global Time Date 23 59 00 31 12 99 Dwell Time 5 seconds Video Loss OFF Contact Alarms OFF Auto Cancel OFF Cancel Time 5 Seconds Alarm Queue Type CHRON chronological ...

Страница 22: ... Better than 50dB 5 2 MECHANICAL SPECIFICATION Contact Alarm Inputs Relay Output Communications Ports Local Keyboard Socket Power Input Setup Link Video Inputs with bridged outputs Optional 75Ω termination links Video Outputs DIMENSIONS 19 by 3u 482mm x 132mm x 75mm WEIGHT 3 2kg TEMPERATURE Operational 0 Degrees to 40 Degrees C Storage minus 20 Degrees to plus 60 Degrees C Humidity 10 to 95 Non co...

Страница 23: ... to identify the end of the data Packet The Packet Headers and the Packet Terminator are formed from non printable ASCII characters Commands and data are formed from printable ASCII characters ASCII NUL characters are used to separate data fields Baud rate 9600 baud Parity none Stop bits 1 Flow control none Data bits 8 Pin No Function 1 2 Network RX RX 3 4 Network TX TX 5 Ground 6 7 Telemetry RX R...

Страница 24: ...onnection on the appropriate input Also ensure head type is set to match attached camera Sync Fail reported on used inputs Check that the Camera is logged as being ABSENT in the Camera Options Menu If video loss reporting is not required disable through in the Alarm Options Menu Relay not operating when alarm occurs Ensure that Contact Alarm Reporting is set to ON Keyboard displays Comms Fault Che...

Страница 25: ...Supplementary Information MEYERTECH declare under our sole responsibility that the product to which this declaration relates is in conformity with the protection requirements of council directive 89 336 eec on the approximation of the laws of the member states relating to electromagnetic compatibility when installed in accordance with the instructions given in this manual SIGNED S K MEYERS Directo...

Страница 26: ... any and all other expressed or implied warranties of merchantability or fitness or otherwise Items manufactured by any supplier other than Meyertech Division shall bear only the warranty made by the manufacturer of that product and Meyertech Division assumes no responsibility for the performance or reliability of that product Meyertech Division will not be liable for any special or consequential ...

Страница 27: ...ISSUE 01 Page 27 http www meyertech demon co uk MAN 328 MEYERTECH DIVISION ISSUE 01 9 DOCUMENT HISTORY ZVM 328 Video Matrix Users Manual MAN 328 ISSUE DATE CHANGE RECORD 01 1st October 1997 First Issue ...

Страница 28: ...Page 28 http www meyertech demon co uk MAN 328 MEYERTECH DIVISION ISSUE 01 NOTES ...

Страница 29: ...CH DIVISION ISSUE 01 Office Block One Southlink Business Park Oldham England OL4 1DE Sales Support 44 161 628 8406 2 44 161 628 9811 Email sales meyertech co uk Technical Support Oldham 44 161 628 8406 Email technical meyertech co uk http www meyertech demon co uk ...

Отзывы: