![Zone Spark Скачать руководство пользователя страница 16](http://html2.mh-extra.com/html/zone/spark/spark_user-manual_4019822016.webp)
16
2.
Setting Algorithm for
ElCon Charger
NOTE: Make sure you are near a charging receptacle. Vehicle must be plugged in for
procedure.
a.
Loosen charger from the rear compartment beneath the rear facing seat.
b.
On bottom side of charger, driver side, look for black sticker that says “48
VOLT”. Remove to expose black button.
c.
Press and hold button and connect car to the AC outlet (plug in car). Keep finger
on button.
d.
LED on charger will flash….when it flashes 6 times, remove finger from the
button.
e.
Disconnect AC Power – remount charger to finish procedure.
Note: This corrects the minimal boiling of the batteries, extended charge times, and
thermal cutbacks on charging system.