background image

Page: 3/17 

Important Safeguards 

Important safeguards:

 

* This air-conditioner is suitable for indoor use only rather than for other occasions.

* Rated operating range: this unit shall be connected to 220-240V / 50Hz power output end.

* The  air-conditioner  shall  be  installed  in  accordance  with  the  wiring  rules  of  local  grid  to

ensure proper grounding. Should you have any question about electrical installation, follow

the  User

s  Manual  or  have  the  installation  done  by  professional  electrician  whenever

necessary.

* Please put this unit in a flat and dry place and keep it at least 50cm away from surrounding

objects or walls.

* Once  the  air-conditioner  is  installed,  ensure  that  the  plug  wire  is  in  good  condition  and

inserted firmly into the power socket and always ensure that the power cord is arranged in

order to prevent the personnel from stumbling over it or the plug from being pulled out.

* Do not insert any object into the air inlet/outlet of the air-conditioner. Be sure to keep the air

inlet/outlet of the air-conditioner unblocked. 

* Where there is the need to install a drain pipe, ensure that the connection of the drain pipe is

in good condition without flexure. 

* When adjusting the horizontal/vertical louver at the air outlet, turn it slightly by hand to avoid

damage of the louvre. 

* Keep the unit in an upright position when moving it.

* Keep this unit away from gasoline, flammable gases, oven or other heat sources.

* Do not dismantle, inspect or modify the unit without authorization as this may result in fault

of the unit, and even bodily injury & property damage; to avoid dangers, if the unit is faulty,

be sure to have it repaired by the manufacturer or professionals.

* Do not install and operate this air-conditioner in a bathroom or other wet environments.

* Do  not  allow  the  children  to  play  with  this  machine.  Closely  supervise  the  children  or

disabled people when this unit is in use.

* Do not turn off this unit by removing the plug.

* Do not place such objects as cups on the unit to prevent water or other liquids from spilling

into the air-conditioner. 

* Do not use pest control aerosol or other flammable substances near the air-conditioner.

* Do  not  wipe  or  wash  the  air-conditioner  with  chemical  solvents  such  as  gasolines  and

alcohols, etc. Before cleaning the air-conditioner, be sure to turn off the power supply and

wipe  it  with  soft  semi-wet  cloth;  if  the  machine  is  indeed  very  dirty,  wipe  it  with  neutral

Содержание YPO2-09C

Страница 1: ...Page 1 17 YPO2 09C Portable Air Conditioner User s Manual...

Страница 2: ...Water Drainage Methods 12 Maintenance 13 End of Season Storage 15 Handling of the Unit 14 Troubleshooting 16 Appendix 17 Thank you for selecting this super quality air conditioner Please keep this Use...

Страница 3: ...ction of the drain pipe is in good condition without flexure When adjusting the horizontal vertical louver at the air outlet turn it slightly by hand to avoid damage of the louvre Keep the unit in an...

Страница 4: ...OFF setting Features and Parts 1 Features Brand new appearance compact structure with a sense of streamline The appearance of the unit is beautiful and elegant the remote control can be placed on the...

Страница 5: ...oner in an upright position for at least 2 hours before first use This air conditioner may be moved indoor conveniently leave the air conditioner in an upright position while moving it The air conditi...

Страница 6: ...t of the back shell and the C shape buckle of the heat exhaust hose 1 3 Installation of the heat exhaust hose assembly and unit 1 Pull the end of the heat exhaust hose apart by several turns 2 Hold th...

Страница 7: ...ust the distance of the window sealing board assembly pulled apart so that the two ends of the assembly come into contact with the window frame and fasten the parts of the assembly with copper screws...

Страница 8: ...structions of the control panel 1 Select the operation interface depending on the models and functions The operation interfaces of the cooling only and cooling heating models are as follows 1 Cooling...

Страница 9: ...mpressor shuts down When the ambient temperature rises to be 17 the compressor starts again The start stop of the compressor meets the requirement for 3 minute protection time The fan is forced to swi...

Страница 10: ...ton to decrease the temperature and timing value 7 F button press this button to switch between the Celsius degree and Fahrenheit degree 8 Cool button press this button to set this unit to operate in...

Страница 11: ...inutes continuously the unit enters fluorine free protection the compressor and water spraying motor turn off the fan operates in the low speed mode and E3 is displayed Remote Control 1 2 3 4 5 6 7 C...

Страница 12: ...p tightly Note 1 Turn on the unit only after the water plug and drain cap are installed properly otherwise the condensate of the unit will flow onto the ground or carpet Drain cap Water plug Figure 12...

Страница 13: ...ilter frame gently in the direction shown by the arrow as shown in Figure 12 2 Grip the gripping position of the evaporator filter mesh and condenser filter mesh and take out the filter mesh gently in...

Страница 14: ...ame in the reverse order of removal Be sure to install the filter mesh first before the filter frame is installed 2 Install the filter frame gently so as not to damage it 3 Cleaning of the handle posi...

Страница 15: ...g the power plug wrap the power cord around the wire winding post insert the plug into the universal jack at the back shell of the unit install the water plug and drain cap 4 Remove the heat exhaust h...

Страница 16: ...dirty Clean or replace the filter mesh Air inlet or air outlet clogged Remove the obstruction Large noise Air conditioner not put on a flat surface Put the air conditioner in a flat and firm place may...

Страница 17: ...gram of the air conditioner For specific technical parameters of the models refer to the nameplate on the product s Disposal do not store waste products with other non classified wastes Such wastes sh...

Отзывы: