background image

2

© Copyright 2015 Zoeller

®

 Co. All rights reserved.

Performance Data

Limited Warranty 

etc. in all pumping applications.  The warranty set out in the paragraph above 

is in lieu of all other warranties expressed or implied; and we do not authorize 

any representative or other person to assume for us any other liability in con-

nection with our products.

Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211, 

Attention: Customer Service Department to obtain any needed repair or replace-

ment of part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, CON-

SEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EXPRESSED 

OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF FITNESS 

FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL BE 

LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

013859XP

Each Zoeller X600 Series Pump installation is required to have a completed Zoeller Pump Company Start-up Report (FM0990). The report is to be completed 

by an approved Start-up Technician in the presence of the installing contractor. A copy of this report will be on file at the Zoeller Pump Company offices in 

Louisville, KY.  

Failure to comply with the requirement will void the warranty agreement.

Manufacturer warrants, to the purchaser and subsequent owner during the 

warranty period, every new product to be free from defects in material and 

workmanship under normal use and service, when properly used and main-

tained, for a period of one year from date of purchase by the end user, or 18 

months from date of original manufacture of the product, whichever comes first.  

Parts that fail within the warranty period, one year from date of purchase by the 

end user, or 18 months from the date of original manufacture of the product, 

whichever comes first, that inspections determine to be defective in material or 

workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit.  No allowance 

will be made for shipping charges, damages, labor or other charges that may 

occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any material 

or product that has been disassembled without prior approval of Manufacturer, 

subjected to misuse, misapplication, neglect, alteration, accident or act of 

nature; that has not been installed, operated or maintained in accordance with 

Manufacturer's installation instructions; that has been exposed to outside sub-

stances including but not limited to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other 

abrasive or corrosive substances, wash towels or feminine sanitary products, 

X611

X621

X631

X641 

(1 PH)

X641

X651 

(1 PH)

X651

X661

MODEL

MODEL

PUMP PERFORMANCE CURVE

MODELS X611/X621/X631/X641/X651/X661

X611 X621

X631

X641

X651

X661

X641  1 PH

X651  1 PH

Содержание X600 Series

Страница 1: ...tor ____________________________________________ Sales Order Number ____________________________________ Contractor ____________________________________________ Date of Installation _____________________________________ System Readings During Operation Voltage ____ Amps _____ Table of Contents Safety Instructions 1 Limited Warranty 2 Performance Data 2 Preinstallation Information 3 Electrical Data...

Страница 2: ...ent will void the warranty agreement Manufacturer warrants to the purchaser and subsequent owner during the warranty period every new product to be free from defects in material and workmanship under normal use and service when properly used and main tained for a period of one year from date of purchase by the end user or 18 months from date of original manufacture of the product whichever comes f...

Страница 3: ...ed periodically for clogging and cleaned as necessary Trapped air is caused by agitation and or a dry basin 4 Water hammer creates momentary high pressure surges These surges can cause severe damage to check valves and the piping system Consideration for water hammer must be included in the piping system design ReferenceASPE Data Book Chapter 2 33 Some systems may require external spring or lever ...

Страница 4: ...p NOTE The hole must be below the basin cover and cleaned periodically Water stream will be visible from this hole during pump run periods Also a vent hole is drilled in the pump housing Be sure that this hole is cleared during any servicing 7 Vent gases and odors to the atmosphere through vent pipe per Local and State codes 8 Secure power cord to avoid entanglement with variable level float switc...

Страница 5: ... leak probes are housed An indicator light will activate whenever water is present in the cavity Whenever the seal leak light is activated indicating that the lower seal has failed the pump should be removed and serviced in order to avoid damage to the motor 3 The green wire shall be connected to a ground lug in the panel CONTROL PANELS These pumps require a control panel The control panel rarely ...

Страница 6: ... RUN CAP 324 389UF 125V START CAP ZEPA0477 5 4 1 6 2 WHITE RED PUMP MAIN START L1 L2 BLACK WHITE 230 VAC 1ø FROM CONTACTOR RUN START BLACK START RELAY CAPACITOR CAPACITOR 1 2 3 GREEN Three phase pumps are nonautomatic To operate automatically a control panel with level control is required Follow the instructions provided with the panel to wire the system Before installing a pump check the pump rot...

Страница 7: ...es should be placed in the fully open position Sys tems should not be operated for extended periods of time with the discharge valves partially closed due to damaging the valve SHUTDOWN PROCEDURES Ifasystemisshutdownformorethansixmonths thefollowingisrecommended Pumps If pit is to remain dry then the pump can remain in the pit With the pump in the pit it should be operated for five minutes once ev...

Страница 8: ...period or use Increase Pipe Friction Clogged line or check valve Abrasive material chemical deteriorated impeller and pump housing If the above check list does not uncover the problem consult the factory Do not attempt to service or otherwise disassemble pump Service Checklist Trouble Shooting Steps Check Voltage At If No Voltage If Voltage No 1 Line terminals in pump s Check Disconnect switch lin...