background image

2

© Copyright 2017 Zoeller

®

 Co. All rights reserved.

If the above checklist does not reveal the problem, consult the Product Support Department.  Do not attempt to service or otherwise 

disassemble pump. Service must be peformed by a Zoeller Authorized Service Station. Go to www.zoellerpumps.com/servicestations to find 

the Authorized Service Station in your area.

SERVICE CHECKLIST

Manufacturer warrants, to the purchaser and subsequent owner during 

the warranty period, every new product to be free from defects in material 

and workmanship under normal use and service, when properly used and 

maintained, for a period of three years from date of manufacture. Parts that fail 

within the warranty period, that inspections determine to be defective in material 

or workmanship, will be repaired, replaced or remanufactured at Manufacturer's 

option, provided however, that by so doing we will not be obligated to replace 

an entire assembly, the entire mechanism or the complete unit. No allowance 

will be made for shipping charges, damages, labor or other charges that may 

occur due to product failure, repair or replacement.

This warranty does not apply to and there shall be no warranty for any 

material or product that has been disassembled without prior approval of 

Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident 

or uncontrollable act of nature; that has not been installed, operated or 

maintained in accordance with Manufacturer's installation instructions; that has 

been exposed to outside substances including but not limited to the following:  

sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, 

gasoline, solvents, etc.), or other abrasive or corrosive substances, wash 

towels, etc. in all pumping applications.  The warranty set out in the paragraph 

above is in lieu of all other warranties expressed or implied; and we do not 

authorize any representative or other person to assume for us any other 

liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky  40211 

USA, Attention: Customer Support Department to obtain any needed repair 

or replacement of part(s) or additional information pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL, 

CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY 

OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY 

SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitations on the duration of an implied warranty, 

so the above limitation may not apply to you. Some states do not allow the 

exclusion or limitation of incidental or consequential damages, so the above 

limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and you may also have other 

rights which vary from state to state.

LIMITED WARRANTY

DO’S & DON'T’S FOR INSTALLING UNIT

   1. 

DO

 read all installation material with the unit.

   2. 

DO

 inspect unit for any visible damage caused by shipping.  Contact dealer 

if unit appears to be damaged.

   3. 

DO

 remove all debris from the basin.  Be sure that the pump will have a 

hard, level surface beneath it.  

DO

 

NOT

 install on sand, gravel or dirt.

   4. 

DO

 be sure that the area is large enough to allow proper clearance for the 

level control switch(es) to operate properly.

   5. 

DO Always Disconnect Pump From Power Source Before Handling

.

   DO 

always connect to a separately protected and properly grounded circuit.

   DO

 

NOT

 ever cut, splice, or damage power cord (Only splice in a watertight 

junction box).

   DO

 

NOT

 carry or lift pump by its power cord.

   DO

 

NOT

 use an extension cord.

   6. 

DO

 install a check valve and a union in the discharge line.

   DO

 

NOT

 use a discharge pipe smaller than the pump discharge.

 7. 

DO

 

NOT

 utilize this unit for pumping gasoline or other hazardous liquids.

 8. 

DO

 test pump immediately after installation to be sure the system is 

working properly.

 9. 

DO

 review all applicable governing codes and verify that the installation 

conforms to each of them.

 10. 

DO consult manufacturer for clarifications or questions.

 11. 

DO

 consider a two-pump system with an alarm where an installation may become 

overloaded or primary pump failure would result in property damages.

 12. 

DO

 consider a D.C. Backup System where a sump or dewatering pump is 

necessary for the prevention of property damages from flooding due to A.C. 

power disruptions, mechanical or electrical problems or system overloading.

  13. 

DO

 inspect and test system for proper operations at least every 3 months.

CONDITION

COMMON CAUSES

A.  Pump will not start or run.

Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically, 

defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective, 

damaged, or out of adjustment.

B.  Motor overheats and trips overload 

or blows fuse.

Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defec-

tive capacitor or relay, motor shorted.

C.  Pump starts and stops too often.

Float tight on rod, check valve stuck or none installed in long distance line, overload open, level switch(s) defec-

tive, sump pit too small.

D.  Pump will not shut off.

Debris under float assembly, float or float rod bound by pit sides or other, switch defective, damaged or out of adjustment.

E.  Pump operates but delivers little or 

no water.

Check strainer housing, discharge pipe, or if check valve is used vent hole must be clear. Discharge head 

exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water 

containing air or causing air to enter pumping chamber.

F.  Drop in head and/or capacity after 

a period of use.

Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly 

deteriorate impeller and pump housing. Check line. 

  ELECTRICAL PRECAUTIONS-

 Before servicing a pump, always shut off the main power breaker and then unplug the pump - making 

sure you are wearing insulated protective sole shoes and not standing in water. Under flooded conditions, contact your local electric company or a 

qualified licensed electrician for disconnecting electrical service prior to pump removal.

 Submersible pumps contain oils which becomes pressurized and hot under operating conditions. 

Allow 2-1/2 hours after disconnecting 

before attempting service.

In those instances where damages are incurred as a result of an alleged pump failure, 

the Homeowner must retain possession of the pump for investigation purposes.

Содержание SHARK Series

Страница 1: ...ng or removing cutter 1 ZoellerGrinderPumpsaredesignedforgrindingandpumpingsewagefromhomes The pump is intended to grind and pump all normal sewage including reasonable quantities ofdisposablediapers...

Страница 2: ...OT install on sand gravel or dirt 4 DO be sure that the area is large enough to allow proper clearance for the level control switch es to operate properly 5 DO Always Disconnect Pump From Power Source...

Страница 3: ...y and all codes 11 For nonautomatic pumps locate float switches as shown in sketches The best place for the off point is above the motor housing and positioned 180 from the inlet Never put off point b...

Страница 4: ...177 C to soften the thread lock sealer on the bolt for ease of removal Remove the bolt by turning in a counterclockwise rotation It will be necessary to use a wood block to prevent the rotor from turn...

Страница 5: ...de alivio de tensi n y no conecte un conductor directamente a la bomba Si est da ado el cable el ctrico se debe reemplazarlo un representante authorizado por Zoeller 9 La bomba contiene aceite lo que...

Страница 6: ...nte cuando hay una caja de conexi n herm tica NO transporte o levante la bomba por su cable de alimentaci n el ctrica NO use un cable de extensi n 6 INSTALE una v lvula de retenci n y una uni n en la...

Страница 7: ...os interruptores de flotador es como se muestra en los esquemas El punto off apagado debe estar por encima de la carcasa del motor y a 180 de la entrada Nunca ubicar el punto off d bajo de la entrada...

Страница 8: ...n centro de servicio autorizado 2 Limpie a fondo el cortador en forma de estrella y el conjunto de disco de acero inoxidable Incline la bomba hacia atr s hacia la posici n vertical para asegurarse de...

Страница 9: ...e d lectrocution L usage de ce type de pompe dans une piscine de natation et des zones marines n a pas t tudi 12 Il ne faut pas essayer de tourner avec les doigts le couteau qui se trouve au fond de l...

Страница 10: ...rs brancher la pompe sur un circuit s par mis la terre IL NE FAUT JAMAIS couper faire une pissure ou endommager un cordon d alimentation Pour faire une raccordement il faut utiliser un bo tier de racc...

Страница 11: ...strations Le point d arr t doit tre au dessus du carter du moteur et 180 de l admission Le point d arr t ne se doit trouver jamais au dessous du refoulement de la pompe 12 Pour viter la propagation de...

Страница 12: ...yer soigneusement le rotor et le disque Incliner la pompe la verticale pour s assurer que le jeu axial a t retir V rifier et noter le d gagement entre le rotor et le disque l aide d une jauge d paisse...

Отзывы: