© Copyright 2018 Zoeller Co. All rights reserved.
- 9 -
Carbon filter vent
(1) Open the cover.
(2) Replace the carbon filter.
To maintain effective ventilation, please replace the carbon filter periodically.
EA0056
Replace the carbon filter
STEP 7
1) Install the closet bolts at the points marked earlier.
2) Place the toilet assembly over the closet bolts. Install
the anchoring hardware and tighten in an alternating
pattern. Check for level and shim as required. Be
careful when tightening bolts or nuts against china
to avoid cracking the china.
3) Install rubber bellows onto the toilet discharge and
grinder tank hub and secure with the worm clamps
provided for installation. See sketch in Step 3. For
built-in installation, install the rubber couplings to both
the grinder tank and the toilet discharge and secure
to extension pipe with worm clamps provided. See
sketch in Step 4.
4) Install the water supply line from the existing water
shut-off valve to the toilet water supply connection.
5) Open the water supply valve and check for leaks.
The toilet tank should to the proper level. Adjust
if required.
6) Plug the pump's power cord into the outlet.
7) Flush the toilet and watch for proper operation. Listen
for the pump to start. The pump unit requires proper
venting in order for toilet to
Check for leaks.
8) Repeat
cycles to assure proper operation.
FLOOR LEVEL TO WITHIN 3 mm (1/8")
PUMP UNIT
AUX. INLET
WATER
SUPPLY
OUTLET
DISCHARGE
PIPE
CARBON FILTER VENT
EA0065
STEP 6
Toilet Installation (Toilet Supplied by Others)
(PLEASE REPLACE THE
CARBON FILTER
PERIODICALLY.)