Страница 1: ...en you see this symbol on the pump or in the manual look for one of the following signal words and be alert to the potential for personal injury or property damage Warns of hazards that WILL cause serious personal injury death or major property damage Warns of hazards that CAN cause serious personal injury death or major property damage Warns of hazards that CAN cause personal injury or property d...

Страница 2: ...ife expectancy can occur if the ground water is not cold 86 ºF 30 ºC or contains air or gases 9 DO NOT run the pump dry DO NOT run the pump with a completely closed discharge DO NOT pump chemical or corrosive liquids Failure to follow above warnings could result in damage to the pump voiding the warranty and causing personal injury 10 CAUTION Check to be sure your power source is capable of handli...

Страница 3: ...nstallation of jet pumps 2 Plastic pipe must have a minimum pressure rating of 160 PSI WELL TO PUMP PIPING 1 All offset piping should slope upwards from well to pump 2 Avoid dips or pockets in offset piping or air will accumulate at high points which will make priming difficult 3 Install unions at pump and at well to aid in servicing 4 Allow enough room around pump and piping installation for usin...

Страница 4: ...r change the red and gray wire to voltage required Figure 5 Dual Voltage Wiring Diagram 2 To change voltage remove the rear access cover of the motor which is held in place with two 2 screws Change the red and gray wire on the transfer switch board to the voltage required Replace rear access cover before starting or operating pump Failure to do so can result in personal injury 3 Your pump motor ha...

Страница 5: ... bracket MOTOR REPLACEMENT Figure 5 1 Uni Frame motors can be replaced in the field with any standard Nema J jet pump motor by following the following instructions CAUTION Before attempting to replace the motor make certain that the power supply is disconnected and the system pressure is relieved 2 Remove pump body Ref No 8 diffuser Ref No 7 impeller Ref No 6 and shaft seal Ref No 4 by following s...

Страница 6: ... 2 Clean or replace defective control 3 Adjust switch settings Clean contacts with emery cloth if dirty 4 Repair leaks as necessary 5 Make sure above ground connections are tight Then repeat test If necessary pull piping and repair leak 6 Repair or replace Pump won t shut off 1 Wrong pressure switch setting or setting drift 2 Defective pressure switch 3 Loss of prime 4 Low well level 5 Fouled ejec...

Страница 7: ...HORSEPOWER 1 2 3 4 MODEL NO PART NO 460 0006 461 0006 DESCRIPTION QTY 1 Motor Nema J Thd Motor Cover w Screws Screws Cover Motor Lead Wire 021301R 021302 136135A 98J105 1 2 1 98J107 1 2 1 2 3 Mounting Ring Hex Hd Cap Screws 3 8 x 3 4 135314 4 135314 4 4 5 6 7 8 9 10 Ring Square Cut Seal Rotary w Spring Impeller Diffuser Rubber Diffuser Pump Body Plug Priming 131100 132428 132583 1 139348 132424 1 ...